3.2 User codes setting
There can be up to 14 different user codes for individual users. The system stores
to its memory which code was used for what event and when. This data can go to a
Central monitoring station as well and can also be viewed by a PC with Comlink
software.
All user codes are empty as a factory default and the supervisor should program
them entering:
F 6 xxxx yy zzzz
where
xxxx
is the master code,
yy
is the user code index (from 01 to 14) and
zzzz
is the new user code.
Example:
If the master code is 1234 and the user 3 new code should be 5277 enter:
F 6 1234 03 5277
To delete a particular user code,
enter 0000 as the new code (combination
0000 can not be used as a valid code).
Example:
If the master code is 1234 the user 3 code can be deleted by:
F 6 1234 03 0000
Notes:
•
You can program new codes only when the system is disarmed.
•
The supervisor should record the codes to the table on last page of this
manual (it should be kept hidden in a safe place).
•
The JA-60D keypad has its own access codes, which can be different from
the other keypads in the system. See the JA-60D manual for details.
•
If the system is split, the supervisor can change the user codes, but can
not change to which section the particular code belongs (only the installer
can change this).
3.3 Internal clock setting
The control panel has a built in real time clock. All events are stored to the event
memory including the time & date. The clock should be set after installation, but
the supervisor can set the clock while in the user mode.
To switch the control panel to the user mode enter
F 0 master code
. User
mode will be indicated by a
U
on the keypad. To set the clock enter:
4 hh mm DD MM YY
where:
hh
= hours;
mm
= minutes;
DD
= day;
MM
= month and
YY
= year
Example: at 21:30 on March 19. 2005 enter: 4 21 30 19 03 04
To
exit user mode
press
N
.
Alarm system JA-63 „PROFI“
- 9 -
MGK51501