Note: features of this system can be substantially modified by programming
during installation. The installer should instruct the users how to operate and test
the system.
1 Indicators
The alarm system’s status is indicated on the keypad. There can be multiple
keypads in the system and in such a case all keypads will have identical
functions. A keypad’s LED indicators and display inform the user about the
conditions of the system.
LED indicators:
Alarm:
alarm triggered by an intruder, smoke, gas etc
Tamper:
opened cover, damaged detector, excessive
number of attempts to enter code, etc.
Fault:
power loss, lost communication with a detector
etc., (view details by pressing
N
)
Battery:
battery of the device specified on the display is
low. See battery replacement section.
information received from a wireless item or wireless
communication of the keypad in progress
Armed:
continues = armed, slow blinking = exit delay,
fast blinking = entrance delay
Power:
continues = AC power & back up battery O.K.,
blinking = failure (AC or back up battery), off = control
panel is not powered
88
display specifies event source:
wireless
detector 12
indicated event (Alarm, Tamper, Failure or
Battery) was caused by detector number 12
wired zone 2
indicated event (Alarm, Tamper, Failure or
Battery) was caused by wired zone number 2
wireless
controller 3
indicated event was caused by wireless
controller (remote control, keypad, Panic button)
number 3
Control panel
indicated event (Tamper or Failure) was caused
by the control panel
Wireless siren
indicated event (Tamper, Failure or Battery)
was caused by the outdoor wireless siren
Sub control
panel
indicated event (Alarm, Tamper, Failure or
Battery) was caused by the sub control panel
Alarm system JA-63 „PROFI“
- 3 -
MGK51501