Note:  features of this system can be substantially modified by programming 
during installation. The installer should instruct the  users how to operate and test 
the system. 

1 Indicators 

 

The alarm system’s status is indicated on the keypad. There can be multiple 

keypads in the system and in such a case all keypads will  have identical 
functions. A keypad’s LED indicators and display inform the user about the 
conditions of the system. 

 

 

LED indicators: 

 

Alarm: 

alarm triggered by an intruder, smoke, gas etc

 

Tamper: 

opened cover, damaged detector, excessive 

number of attempts to enter code, etc.  

Fault: 

power loss, lost communication with a detector 

etc., (view details by pressing 

N

Battery: 

battery of the device specified on the display is 

low. See battery replacement section. 

 information received from a wireless item or wireless 

communication of the keypad in progress   

Armed: 

continues = armed, slow blinking = exit delay, 

fast blinking = entrance delay 

Power: 

continues = AC power & back up battery O.K., 

blinking = failure (AC or back up battery), off = control 
panel is not powered 

 

88

 display specifies event source: 

 

wireless 

detector 12  

indicated event (Alarm, Tamper, Failure or 

Battery) was caused by detector number 12  

 

wired zone 2 

indicated event (Alarm, Tamper, Failure or 

Battery) was caused by wired zone number 2 

 

wireless 

controller 3 

indicated event was caused by wireless 

controller (remote control, keypad, Panic button)  

number 3 

 

 

Control panel 

indicated event (Tamper or Failure) was caused 

by the control panel  

 

Wireless siren 

indicated event (Tamper, Failure or Battery)  

was caused by the outdoor wireless siren 

 

Sub control 

panel 

indicated event (Alarm, Tamper, Failure or 

Battery) was caused by the sub control panel  

Alarm system JA-63 „PROFI“ 

- 3 - 

MGK51501 

Summary of Contents for JA-63 PROFI"

Page 1: ...JA 63 Profi User manual Pod Skalkou 33...

Page 2: ...2 11 Appliance control 8 3 User s settings 8 3 1 New master code 8 3 2 User codes setting 9 3 3 Internal clock setting 9 3 4 Automatic arming disarming 10 3 5 Bypass 10 4 Telephone communicator progra...

Page 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Page 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Page 5: ...11 press the A button system will beep once and the exit delay countdown will start B A ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exi...

Page 6: ...depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the JA 60D keypad enter F7 On the remote control RC 11 press the A an...

Page 7: ...stem history can be viewed using a PC with Comlink software Alarms and failures can also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times...

Page 8: ...ntrol an electrical appliance light heating ventilation etc In such a case users can operate the device Locally with keypad entering F81 ON or F80 OFF The JA 60D keypad does not support this feature R...

Page 9: ...the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in a safe place The JA 60D keypad has its own access codes which can be...

Page 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Page 11: ...mmunicator and if the installer enabled the supervisor to modify the communications settings only then will the following programming be possible 4 1 Telephone communicator testing Testing is possible...

Page 12: ...user mode To switch the control panel to the user mode enter F 0 master code User mode will be indicated by a U on the keypad If Jablotron s SMS server service is provided in your country check with...

Page 13: ...8 Pager dialing can be deleted with 7 F0 F5 To exit user mode press N 5 System testing The supervisor should test the system monthly For testing the control panel should be in the user mode Enter F0 m...

Page 14: ...l battery capacity can shorten the battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be...

Page 15: ...Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 SMS message o Pager Timers exit entrance del...

Page 16: ...location in the house detectors type reaction A B S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 WIRELESS DETECTORS 16 1 2 3 WIRED INPUTS 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Reviews: