background image

c.  multiple pressing and holding of the keys (2 or 3) will switch the 

bypass on – off – on – off …  

4.  By repeating step 3. you can bypass all required alarm sources. 

• 

To close the Bypass menu press the 

N

 key. If anything is bypassed when 

arming, four beeps will sound and 

b

 will be displayed on the keypad during the 

exit delay (and partial arming will be recorded to the memory). 

• 

All bypasses selected with key 

2

 (next arming period bypasses) will switch off 

automatically with the first following disarming. 

• 

The existing bypass setting can be checked or modified in the bypass menu. 

• 

All bypasses can be deleted by key 

4

 in the bypass menu. They can also be 

deleted by the programming mode opening or if the control panel is 
disconnected from the power completely (AC & back up battery).  

 

To 

exit user mode

 press 

N

 

4  Telephone communicator programming 

 

If the control panel is equipped with a telephone communicator and if the 

installer enabled the supervisor to modify the communications settings, only then 
will the following programming be possible.  

 

4.1  Telephone communicator testing 

 

Testing is possible in the user mode. To switch the control panel to the user 

mode enter 

F 0 master code

. User mode will be indicated by a 

U

 on the keypad.   

 

Entering 

89

 will cause the communicator to send voice message number 2 to all 

programmed telephone numbers. It will also send an SMS message if 
programmed (see section 4.2). The telephone line signals will be audible from the 
control panel’s built in speaker during the test (if the dialer is triggered by an alarm 
in normal operation, it will call silently). Testing can be terminated with the 

N

 key. 

 

 

 

Notify the people 

who will be called before testing! 

 

To 

exit user mode,

 press the 

key. 

 

4.2  Telephone numbers for voice message sending 

 

Up to 4 telephone numbers can be programmed in the user mode. To switch the 

control panel to the user mode enter 

F 0 master code

. User mode will be 

indicated by a 

U

 on the keypad.   

Alarm system JA-63 „PROFI“ 

- 11 - 

MGK51501 

Summary of Contents for JA-63 PROFI"

Page 1: ...JA 63 Profi User manual Pod Skalkou 33...

Page 2: ...2 11 Appliance control 8 3 User s settings 8 3 1 New master code 8 3 2 User codes setting 9 3 3 Internal clock setting 9 3 4 Automatic arming disarming 10 3 5 Bypass 10 4 Telephone communicator progra...

Page 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Page 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Page 5: ...11 press the A button system will beep once and the exit delay countdown will start B A ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exi...

Page 6: ...depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the JA 60D keypad enter F7 On the remote control RC 11 press the A an...

Page 7: ...stem history can be viewed using a PC with Comlink software Alarms and failures can also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times...

Page 8: ...ntrol an electrical appliance light heating ventilation etc In such a case users can operate the device Locally with keypad entering F81 ON or F80 OFF The JA 60D keypad does not support this feature R...

Page 9: ...the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in a safe place The JA 60D keypad has its own access codes which can be...

Page 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Page 11: ...mmunicator and if the installer enabled the supervisor to modify the communications settings only then will the following programming be possible 4 1 Telephone communicator testing Testing is possible...

Page 12: ...user mode To switch the control panel to the user mode enter F 0 master code User mode will be indicated by a U on the keypad If Jablotron s SMS server service is provided in your country check with...

Page 13: ...8 Pager dialing can be deleted with 7 F0 F5 To exit user mode press N 5 System testing The supervisor should test the system monthly For testing the control panel should be in the user mode Enter F0 m...

Page 14: ...l battery capacity can shorten the battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be...

Page 15: ...Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 SMS message o Pager Timers exit entrance del...

Page 16: ...location in the house detectors type reaction A B S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 WIRELESS DETECTORS 16 1 2 3 WIRED INPUTS 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Reviews: