c. multiple pressing and holding of the keys (2 or 3) will switch the
bypass on – off – on – off …
4. By repeating step 3. you can bypass all required alarm sources.
•
To close the Bypass menu press the
N
key. If anything is bypassed when
arming, four beeps will sound and
b
will be displayed on the keypad during the
exit delay (and partial arming will be recorded to the memory).
•
All bypasses selected with key
2
(next arming period bypasses) will switch off
automatically with the first following disarming.
•
The existing bypass setting can be checked or modified in the bypass menu.
•
All bypasses can be deleted by key
4
in the bypass menu. They can also be
deleted by the programming mode opening or if the control panel is
disconnected from the power completely (AC & back up battery).
To
exit user mode
press
N
.
4 Telephone communicator programming
If the control panel is equipped with a telephone communicator and if the
installer enabled the supervisor to modify the communications settings, only then
will the following programming be possible.
4.1 Telephone communicator testing
Testing is possible in the user mode. To switch the control panel to the user
mode enter
F 0 master code
. User mode will be indicated by a
U
on the keypad.
Entering
89
will cause the communicator to send voice message number 2 to all
programmed telephone numbers. It will also send an SMS message if
programmed (see section 4.2). The telephone line signals will be audible from the
control panel’s built in speaker during the test (if the dialer is triggered by an alarm
in normal operation, it will call silently). Testing can be terminated with the
N
key.
Notify the people
who will be called before testing!
To
exit user mode,
press the
N
key.
4.2 Telephone numbers for voice message sending
Up to 4 telephone numbers can be programmed in the user mode. To switch the
control panel to the user mode enter
F 0 master code
. User mode will be
indicated by a
U
on the keypad.
Alarm system JA-63 „PROFI“
- 11 -
MGK51501