9
5.2 PARAMETER SETTING
To turn the machine
on, press
and hold the keys simultaneously.
When the display shows F.01, release the keys.
The key
scrolls the parameters while the key
confirms the selected
parameter. To quit programming, turn the machine off and on again.
Note. It is recommend to use the default parameters set by the
manufacturer (see Par. 5.5).
5.3 PARAMETERS
PARAMETER
DISPLAY
DESCRIPTION
F.01
°F
Unit for measuring degrees in Fahrenheit
°C
Unit for measuring degrees in Celsius
F.02
2
Enabling coffee dispensing (channel 1)
3
Enabling water and steam dispensing
(channel 2)
4
Not used
5
Enabling water and steam
dispensing (channel 1 and 2)
6
Not used
7
Enabling water and steam
dispensing (channel 1 and 2)
with prevalence for coffee dispensing.
When the coffee channel is in the ON
position, it disables the water and steam
channel. When the
coffee channel is in the OFF position, it