10
enables the water and steam channel.
T1
XX
Where XX indicates the coffee
temperature setpoint
T2
XX
Where XX indicates the water and
steam temperature setpoint
T3
XX
Not used
E1
X
Where X indicates the correction factor
of the coffee channel
E2
X
Where X indicates the correction factor
of the water and steam channel
E3
X
Not used
5.4 PRESET PARAMETERS
It is possible to reconfigure the Display with default parameters (factory
settings) using the PRESET operation.
To perform the PRESET, press the key
and turn on the machine. When the
display shows PrS, release the key and turn the machine off and then on
again.
5.5 DEFAULT PARAMETERS
CELSIUS
FAHRENHEIT
Parameters
Display
Parameters
Display
F.01
°C
F.01
°F
F.02
5
F.02
5-7
P
1.3
P
1.3
I
006
I
006
D
1.5
D
1.5
T1
93
T1
200
T2
123 (min 121-
max 128)
T2
255 (min 248-
max 626)
T3
0
T3
0