6
Outputs
Powered mechanical relays (0 or 6
depending on model code):
Pre-powered on circuit board switching line voltage
6 A (resistive), 1/8 HP (93 W)
All six relays are fused together as one group, total current for this group
must not exceed 6A
Dry contact mechanical relays (0, 2
or4 depending on model code):
6 A (resistive), 1/8 HP (93 W)
Dry contact relays are not fuse protected
Pulse Outputs (0, 2 or4 depending on
model code):
Opto-isolated, Solid State Relay
200mA, 40 VDC Max.
VLOWMAX = 0.05V @ 18 mA
Accuracy (0-10 Hz): ± 0.5% of Pulse Rate, (10-20 Hz): ± 1.0%, (20-40
Hz): ± 2.0%
4 - 20 mA (0 or 2)
Internally powered
Fully isolated
600 Ohm max resistive load
Resolution 0.0015% of span
Ethernet
10/100 802.3-2005
Auto MDIX support
Auto Negotiation
USB
Connector: Type A receptacle
Speed: High speed (480 Mbit)
Power: 0.5 A maximum
Battery (Real-Time Clock)
Model BR2032, 3-volt Lithium Coin Cell 20 mm diameter
Agency Approvals:
EMC
UL 61010-1:2012 3rd Ed + Rev:2019
CSA C22.2 No. 61010-1:2012 3rd Ed. + U1; U2
IEC 61010-1:2010 3rd Ed. + A1:2016
EN 61010-1:2010 3rd Ed. + A1:2019
BS EN 61010-1:2010 + A1:2019
EMC
IEC 61326-1:2020
EN 61326-1:2013
BS EN 61326-1:2013
For EN 61000-4-3 Radiated RF Immunity, the controller meets Performance Criteria B. In environments where severe radio-frequency
interference (RFI) is present, the controller may reboot/restart. If this occurs, the controller should be relocated away from the electromagnetic
interference (EMI) source.
*Class A equipment: Equipment suitable for use in establishments other than domestic, and those directly connected to a low voltage
(100-240 VAC) power supply network which supplies buildings used for domestic purposes.
2.3 Intended Use
The Walchem Intuition-6 is a microprocessor-based measuring and control instrument used to measure water quality param-
eters and other process variables in a wide range of water and wastewater treatment applications. Operating the instrument
in any way other than as described in these instructions may compromise the safety and function of the measuring system
and is therefore impermissible. Electrical connection work and maintenance work may only be carried out by qualified per
-
sonnel. The manufacturer is not liable for damage caused by improper or non-designated use.
2.4 Mechanical
Enclosure Material
Polycarbonate
Enclosure Rating
NEMA 4X (IEC 60529 to IP66)
Dimensions
11.1” x 8.3” x 5.5” (282 mm x 211 mm x 140 mm)