Technical information
AirModule 6 720 813 268(2014/10)
6
4
Technical information
4.1
Technical information - heat pump module
Unit
E9
E15
Electrical information
Power supply
V
400
1)
/230
2)
1) 3N AC 50 Hz
2) 1N AC 50 Hz
400
Recommended fuse size
A
16
Immersion heater in steps
kW
3/6/9
3/6/9/12/15
Heating installation
Connection
3)
3) See Connections in safety assembly
Cu 28
Cu 28
Maximum operating pressure
kPa
250
250
Minimum operating pressure
kPa
50
50
Expansion vessel
L
14
14
External available pressure
kPa
4)
4) This depends on the type of heat pump, see tab. 11
Minimum flow
L/s
0.36
0.59
Circulation pump model
Grundfos UPM2 25-75 PWM
Wilo Stratos Para 25/1-11 PWM
Flow max. temperature, booster
only
°C
85
85
General
Hot water cylinder volume
L
190
190
Maximum operating pressure on
tap DHW circuit
MPa
1
Material
Stainless steel 1.4521
IP rating
IP X1
Dimensions (WxDxH)
mm
600x660x1800
Weight
kg
135
Table 3 heat pump module with immersion heater