Commissioning
AirModule –6 720 813 268(2014/10)
39
11.2
System commissioning via configuration wizard
The configuration wizard will automatically detect the BUS units
installed in the system. It will adjust menu and standard settings
accordingly.
System analysis could last up to a minute.
When the configuration wizard has performed the system analysis, the
Startup
menu opens. These settings must be checked and if required
modified, and confirmed.
If system analysis is skipped, the
Startup
menu opens. These settings
must be carefully checked and modified according to the installed
system. Then the settings must be confirmed.
Please note further information on settings in Chapter 12.
Menu Item
Question
Answer/setting
Country information
In which country is the heat pump installed?
Select corresponding country
Storage cylinder
Is there a storage cylinder installed in the system?
No
|
Yes
Start configuration wizard
Would you like to start the configuration wizard?
Yes
|
No
Select an external heat source
What other heat source is used?
Not installed
|
Serial immersion heater
|
Boost.
heater with mixing valve/heat pump alt.
|
Parallel booster heater with mixing valve
|
Hybrid
Heating circuit 1 installed
Is heating/cooling circuit 1 installed? Where is heating circuit 1 connected
electrically?
No
|
On the heat source
|
At the module
Config. VK1 on the heat source
Is heating/cooling circuit 1 a heating circuit without mixing valve connected to
the heat pump module?
No integrated VK1
|
No own heating circuit
pump
|
Via circulation pump PC1
Mixer heating circuit 1
Is heating/cooling circuit 1 a heating/cooling circuit with mixing valve?
Yes
|
No
Mixer runtime heat circ. 1
How long until the mixing valve in heating/cooling circuit 1 moves from one
end position to the other?
0
...
600 s
Heating system heat circ. 1
What type of heating does heating/cooling unit 1 use?
Radiator
|
Convector heater
|
Underfloor
Ctrl type h. circ. 1
How will the temperature influenced by heating circuit 1 be regulated?
Outdoor-temp.-compensated
|
Outside temp.
with low end
Prog. unit Heat. circ. 1
Which user interface or room controller is installed for heating/cooling
circuit 1?
HPC400
|
RC10
Heating circuit 2 installed
, ...
equates to heating circuit 1
Heating circuit 3 installed
, ...
equates to heating circuit 1
Heating circuit 4 installed
, ...
equates to heating circuit 1
DHW system
(
DHW heat pump 1
|
DHW heat
pump 2
)
Is a DHW system installed? How is the DHW system connected?
Off
|
On
DHW circulation pump
installation
Is a DHW circulation pump installed in the DHW system?
No
|
Yes
Solar thermal sys installed
Is a solar heating system installed?
No
|
Yes
Pool 3-way valve
Is there a mixing valve installed for heating of basin/pool? How long does it
take the valve to reach its end positions?
10 s– 6000 s
Electr. anode in cylinder
Is there an electric inert anode installed and connected to the DHW cylinder?
Yes
|
No
Fuse size
Indicate the main fuse of the house
16A
|
20A
|
25A
|
32A
Confirm configuration
Do all the settings correspond with the installed system?
Confirm
|
Back
Table 21 System commissioning via configuration wizard
The DHW system is delivered activated. If the DHW
system is activated, but there is no DHW system
installed, the user interface will indicate an operating
error.
▶ If there is no DHW system installed in the system,
then the DHW system must be deactivated in the
commissioning or DHW menu.