Connection for IP module
AirModule –6 720 813 268(2014/10)
61
19
Connection for IP module
The heat pump module contains an IP module, which can be used to
manage and monitor the heat pump module from a mobile unit. It is used
as an interface between the heating system and a network (LAN) and
enables the SmartGrid function.
Fig. 52 IP module installation
[1]
IP module installation. Tilt the electric box forward to access it
and feed the network cable through the roof (
Fig. 53 IP module
[1]
Connection RJ45
[2]
IP module data plate
Commissioning
The router must be configured as follows:
• DHCP enabled
• Ports 5222 and 5223 may not be blocked from outgoing traffic.
• Free IP address available
• The address filter (MAC filter) must not filter out the module.
During commissioning of the IP module, the following is possible:
• Internet
The module automatically obtains an IP address from the router. The
name and address of the target server are stored in the standard
settings of the module. As soon as an internet connection is
established, the module automatically logs on to the server.
• Local network
The module does not have to be connected to the internet. It can also
be used in a local network. In this case, however, the module cannot
be reached via the internet, and the IP-module software cannot
automatically update.
• The app
IVT Anywhere
When the app is opened for the first time, the predefined login name
and password must be entered. The login information can be found
on the IP-module data plate.
Use of all the functions requires an internet connection
and a router with an available RJ45 output. This may
incur additional costs. Managing the installation from a
cell phone requires the free app
IVT Anywhere
.
6 720 809 156-40.1I
1
Please refer to the router documentation during
commissioning.
NOTICE:
You will lose your login information when you
change IP-module!
Each IP-module has its own unique login information.
▶ Enter your login information after commissioning in
the appropriate field in your operating instructions.
▶ Change the information according to the new IP-
module if it has been changed.
▶ Inform the user.
You can also change the password in the user interface.
2
1
6 720 809 156-41.1I