14
EN
Instruction manual
[F4]
1. Place the machine on a flat surface.
2.
Place container for draining waste oil under the
drain hole.
3.
Screw out the drain plug (32) and wait until waste
oil stops leaking from the drain hole.
4. Screw in the drain plug (32), fill up the oil tank with
new oil.
ATTENTION! Dispose of the waste oil
environmentally safe by taking it to a
proper collecting point!
Air filter (18) maintenance
Regularly examine filtering element (27) of the air
filter (18) (its clogging depends on various ambient
conditions). Clean (or replace) the air filter as often as
required, but no rarer than after 100 operating hours. A
clogged air filter reduces compressor’s efficiency and
leads to the wearing of the compressor.
ATTENTION! Do not twist the filtering
element (27), otherwise it may be
damaged.
1. Place the machine on the flat surface.
2. Unscrew the fixing bolt (if present).
3. Grip with fingers the cover (26) and remove it.
4. Take out the filtering element (27).
5. Cleanse the filtering element (27) in alcohol or solvent.
6. Remove residual alcohol or solvent properly.
7. Set the filtering element (27) into the cover (26).
8.
Place the cover (26) into its location and press it
until plastic pawls are latched. Or tighten the fixing bolt
(if present).
[F5]
Condensate draining
Periodically, as well as after stopping operating (if
operation lasts more than one hour) drain condensate
from the receiver (2). This prevents from forming
corrosion inside the receiver (2).
1. Place the machine on a flat surface.
2.
Place a container for condensate draining under
the machine, under the slide valve (22).
3.
Unscrew and remove the slide valve (22) and wait
until condensate is completely drained and water drops
stop falling from the slide valve (22).
4. Tighten the slide valve (22).
[F6]
Regular inspection of other components
∙
Regularly inspect the receiver (2) for damage or
corrosion signs. In case of damage of the receiver (2),
repairing on your own (mechanically or by welding)
is prohibited. The damaged receiver (2) should be
replaced completely, by an authorized IVT Service
Centre.
∙
Check periodically and regularly the condition of
the safety valve (12) and pressure gauge (9).
∙
Clean properly and periodically the compressor
pump (16).
Inspection of the non-return valve (31) condition
If pressure drops in the receiver (2) at stopped
compressor and cut off compressed air consumers, you
should inspect the non-return valve (31).
1.
Pull out the plug (29), take out the spring (30) and
the non-return valve (31).
2.
Clean (or replace, if necessary) the non-return
valve (31). Clean also the seat where the non-return
valve is located.
3.
Place the non-return valve (31) and the spring (30)
on their locations and tighten the plug (29).
[F7]
Transport
Transport the machine only by the handle (7).
Moving the machine by other elements is prohibited.
Long term storage
If the machine is stored for a long time, oil should be
completely drained from the oil tank.
∙
Do not store device unprotected outdoors or in
damp environment.
∙
Do not lay device on its side for transportation or
storing.
NOTE: when applying to an IVT Service Center because
of problems with the machine, please make sure the oil
tank is filled with 1/3 of the oil volume.
ENVIRONMENTAL PROTECTION
Recycle raw materials instead of
disposing as waste.
Tool, accessories and packaging should be sorted for
environment-friendly recycling.
The plastic components are labeled for categorized
recycling. These instructions are printed on recycled
paper manufactured without chlorine.