background image

6

Operating instructions

LCD Display counters

isiLine 30/31/32/33

The isiLine display counters are battery-powered. They
are controlled by contact or voltage pulses. They may
be used in various applications, like e. g. 
totalising, parts counting, position acquisition, 

differential counting, etc. In addition, the various
models with specific input types may be extended
using control inputs to select operatin modes and set
for almost any application thanks to adjustable opera-
ting modes.

Options: 

x = A: no backlight
x = B: with backlight 

DC input modes:

Count:

Fast and slow counting inputs

INP A:

Fast counting input

INP B:

Slow counting input

Cnt.Dir:

Counting and counting direction input

INP A: Counting 

input

INP B:  Counting direction input

Up.Dn:

Differential counting input

INP A:  Adding counting input
INP B:  Subtracting counting input

Quad:

Phase discriminator input

INP A: 

0° counting input

INP B: 

90° counting input

Quad2:

Phase discriminator input with 

pulse doubling
INP A: 

0° counting input

INP B: 

90° counting input

Each edge of INP A is counted.

Count:

Counting and reset inputs
INP A:

AC/DC counting input

INP B:

AC/DC reset input

Cnt.Dir:

Counting and counting direction input
INP A:

AC/DC counting direction input

INP B:

AC/DC counting input

Up.Dn:

Differential counting input
INP A:

AC/DC subtracting counting input

INP B:

AC/DC adding counting input.

AC input modes:

Table 1

Model

Operating mode

Counting inputs

INP A

INP B

ISI30.010AX01

ISI30.012AX01

ISI30.013AX01

ISI31.010AX01

ISI31.011AX01

ISI31.013AX01

AC/DC 

ISI32.013AX01

ISI33.010AX01

ISI33.011AX01

Count

0

0 ... 0,7 V DC

NPN

0

7 kHz

0

0 ... 0,7 V DC

NPN

30 Hz

10 ... 260 V AC/DC AC/DC

30 Hz

Cnt.Dir/Up.Dn

Up.Dn

Cnt.Dir

Quad/Quad2

NPN

PNP

AC/DC

NPN

PNP

0

0 ... 0,7 V DC

0

4 ... 30 V DC

10 ... 260 V AC/DC

10 ... 260 V AC/DC

0

0 ... 0,7 V DC

0

4 ... 30 V DC

0

7 kHz

12 kHz

30 Hz

30 Hz

0

3 kHz

0

6 kHz

0

0 ... 0,7 V DC

10 ... 260 V AC/DC

0

0 ... 0,7 V DC

0

4 ... 30 V DC

10 ... 260 V AC/DC

10 ... 260 V AC/DC

0

0 ... 0,7 V DC

0

4 ... 30 V DC

NPN

AC/DC

NPN

PNP

AC/DC

AC/DC

NPN

PNP

0

7 kHz

12 kHz

30 Hz

30 Hz

0

3 kHz

0

6 kHz

0

4 ... 30 V DC

PNP

12 kHz

Overview

0

Summary of Contents for isiLine ISI30 Series

Page 1: ...mbH Co P O Box 3360 D 78022 Villingen Schwenningen Telefon 49 0 7720 942 0 Fax 49 0 7720 942 900 www ivo de e mail info ivo de ISI30 31 32 33 Betriebsanleitung Operating instructions Instructions d ut...

Page 2: ...kHz 00 0 7 V DC 10 260 V AC DC 00 0 7 V DC 04 30 V DC 10 260 V AC DC 10 260 V AC DC 00 0 7 V DC 04 30 V DC NPN AC DC NPN PNP AC DC AC DC NPN PNP 07 kHz 12 kHz 30 Hz 30 Hz 03 kHz 06 kHz Optionen x A oh...

Page 3: ...nicht kondensierend Betriebstemperatur 10 60 C Lagertemperatur 20 70 C Hintergrundbeleuchtung externe Spannungsversrogung 24 V DC 20 50 mA Eingangsspezifikation Anschlussbelegung und einstellbare Bet...

Page 4: ...et frei R cksetz eingang NPN GND 0 V DC Hintergrund beleuchtung Hintergrund beleuchtung Schraubklemme 1 und 3 Funktion siehe Tabelle 3 Optokoppler Eingang 10 260 V AC V DC galvanisch entkoppelt aktiv...

Page 5: ...geschirmte Leitungen verweden Sie d rfen das Ger t nur als Einbauger t einsetzen Der Anwendungsbereich des Produktes liegt in indus triellen Prozessen und Steuerungen In den Bereichen von Fertigungsst...

Page 6: ...ad2 Phase discriminator input with pulse doubling INP A 0 counting input INP B 90 counting input Each edge of INP A is counted Count Counting and reset inputs INP A AC DC counting input INP B AC DC re...

Page 7: ...ifetime approximately 8 years at 20 C Working temperature 10 55 C relative humidity 85 without condensation Operating temperature 10 60 C Storage temperature 20 70 C Backlighting external electrical s...

Page 8: ...free not connected NPN reset input GND 0 V DC Backlighting Backlighting Screw terminals 1 and 3 Function see Table 3 Optocoupler input 10 260 V AC V DC galvanic isolation active for High signal Min pu...

Page 9: ...uts so as to obtain the maximum EMC resistance This device only may be used as a panel mounted device Applications of this product may be found in industrial processes and controls in the branch of th...

Page 10: ...mptage 90 Quad2 Entr e de discriminateur de phase avec doublement des impulsions INP A Entr e de comptage 0 INP B Entr e de comptage 90 Chaque front de INP A est compt Count Entr e de comptage et de r...

Page 11: ...ntation Batterie au lithium non rempla able dur e de vie env 8 ans 20 C Temp rature de travail 10 55 C humidit relative 85 sans condensation Temp rature de fonctionnement 10 60 C Temp rature de stocka...

Page 12: ...NPN GND 0 V DC R tro clairage R tro clairage Bornes vis 1 et 3 Fonction voir le Tableau 3 Entr e optocoupleur 10 260 V AC V DC d couplage galvanique actif pour signal Haut Dur e d impulsion min 16 ms...

Page 13: ...e commande afin d obtenir la r sistance CEM maximale Cet appareil ne peut tre utilis qu en tant qu appareil encastr Ce produit trouve son application dans les process industriels et les commandes dans...

Page 14: ...AX01 ISI31 010AX01 ISI33 010AX01 BL BL INP A INP B Reset Mode GND 1 2 3 4 5 6 7 8 Reset Enable max 5 V DC max 30 V DC 24 V DC 20 50 mA max 5 V DC 10 260 10 260 VAC VDC VAC VDC BL BL INP A INP B Common...

Page 15: ...gen Dimensions Dimensions Senkung Af3 DIN 74 Countersinking Af3 DIN 74 Fraisure Af3 DIN 74 1 Schalttafelausschnitt Panel cut out D coupe d encastrement Schalttafelausschnitt Panel cut out D coupe d en...

Page 16: ...R 600 312 11 50 0 2 ES...

Reviews: