background image

 

Ver.1.01 

  CNT-3204IN-USB   

  1   

 

N Series for USB 
Isolated 32-bit Up/Down Counter Unit 

CNT-3204IN-USB 

 

* Specifications, color and design of the products are subject to change 

without notice. 

 

 

This product is a USB 2.0 supporting counter unit, which adds the 
function of counting pulse signals input from external devices through a 
USB port to a PC. 
It has four channels of 32-bit up/down counters, allowing external 
devices such as a rotary encoder and a linear scale to be connected. 
The pulse signal inputting interface is optocoupler isolated. 
Compact design, (188.0(W)×78.0(D)×30.5(H)mm), features flexibility in 
installation. The product can be set on the floor, wall, and inside the 
console or equipment with the DIN rail. 
Input interface of pulse signal is opto-coupler isolated input. 

 

* The contents in this document are subject to change without notice. 
* Visit the CONTEC website to check the latest details. 
* The information in the data sheets is as of June 2020. 

 

Features

 

 

32-bit up-and-down counter 

The 32 bit up-and-down counter could have four channels and up to 
500kHz maximum speed pulse input. Moreover, it can count 2-phase 
signals and mono-phase signals such as a rotary encoder and a linear 
scale. 

Bus isolation 

The USB (PC) is isolated from I/O interface by an isolators, this product 
has excellent noise performance. 

Control input/output signals and input signals for controlling sampling 
functions 

One control input signal and one control output signal are provided for 
each channel. This product can generate an interrupt, output an external 
signal, preset the counter, and clear it to zero when the count value 
matches the arbitrary value that is set. Moreover, this product has input 
signals (start/stop/clock) for controlling sampling functions. 

Compact design not restricting installation location 

Compact design of 188.0(W) × 78.0(D) × 30.5(H) does not require special 
installation location. 

Compatible to USB1.1/USB2.0 

Compatible to USB1.1/USB2.0 and capable to achieve high speed 
transfer at High Speed (480 Mbps) 

Diverse installations such as screw fastening, with 
magnet(optional),and DIN rail mounting are possible 

Installation on the floor / wall /ceiling is possible by screw fastening, with 
magnet, rubber feet, etc. In addition, DIN rail mounting mechanism is 
equipped as standard with the product, making it easy to install the 
product within the panel or the device. 

Easy-to-wire terminal connector adopted 

Adoption of terminal connector (with screws) enables to achieve easy 
wiring. 

Windows compatible driver software 

Using the counter input driver API-CNT(WDM) for USB makes it possible 
to create applications of Windows. In addition, a diagnostic program by 
which the operations of hardware can be checked is provided. 

 
 
 
 
 
 
 
 

 

Specifications

 

 

Function Specifications <1/2> 

Item 

Specification 

Input *1 

  Counter 

  Channel count 

4 channels 

Count system 

Up/down counting (2-phase/Single-phase/Single-phase Input with Gate 
Control Attached) 

Max. count 

FFFFFFFFh (binary data, 32Bit) 

Input type 

Optocoupler isolated input 

Input signal 

Phase-A/UP 1 x 4 channels, Phase-B/DOWN 1 x 4 channels 
Phase-Z/CLR 1 x 4 channels 

Input resistance 

220 

Ω 

(5V external power supply), 690 

Ω 

(12V external power supply) 

Response frequency 

500kHz 50% duty 

External Power 

5VDC±10% or 12VDC±10% 

Digital filter 

0.1µsec - 1.6384msec or not used 
(can be independently set for each channel.) 

Counter start trigger 

Software/External start input/Sampling start trigger 

Counter stop trigger 

Software/External stop input/Sampling stop trigger 

Sampling 

  Sampling start trigger 

Software/External start input/Count match 

Sampling stop trigger 

Software/External stop input/Specification number/ 
Data transfer error/Count match 

Sampling clock 

Sampling timer/External clock input 

Sampling timer 

2µsec - 107sec 25nsec unit (can not be independently set for each 
channel.) 

External sampling start signal 

Isolated TTL level input (Select Rise or Fall) 

External sampling stop signal 

Isolated TTL level input (Select Rise or Fall) 

External sampling clock signal 

Isolated TTL level input (Fall) 

Response frequency 

500kHz 50% duty 

Control 

  Control input signal type 

Optocoupler isolated input 

Control input channel 

1 x 4 channels 

Control input signal 

- Preset (Select Rise or Fall) 
- Zero-clear (Select Rise or Fall) 
- Counter start/stop (Select Rise or Fall) 
- General-purpose input (positive logic) 
Software-selected from among the above four options 

Response time 

100µsec (Max.) 

Interrupt event 

Count match (8 points), Counter error (2 points),   
Sampling factor (6 points), Carry/Borrow (1 points) 

 
*1  Use the shielded cable for this product to meet “CE EMC Directive”. 
 
 
 
 

 

PLUG-IN Electronic GmbH  •  Am Sonnenlicht 5  •  82239 Alling  •  Tel.: +49 (0) 8141 3697-0  •  [email protected]  •  www.plug-in.de

Summary of Contents for CNT-3204IN-USB

Page 1: ...ing with magnet rubber feet etc In addition DIN rail mountingmechanism is equipped as standard with the product making it easyto install the product within the panel or the device Easy to wire terminal connector adopted Adoption of terminal connector with screws enables to achieve easy wiring Windowscompatible driver software Usingthe counter input driver API CNT WDM for USB makes it possible to c...

Page 2: ...s Nottobe excessive Corrosivegases None Line noise resistance 2 Line noise ACLine 2kV SignalLine 1kV IEC61000 4 4Level 3 EN61000 4 4Level 3 Static electricity resistance Touch 4kV IEC61000 4 2Level 2 EN61000 4 2Level 2 Air 8kV IEC61000 4 2Level 3 EN61000 4 2Level 3 Vibration resistance Sweep resistance 10 57Hz semi amplitude vibration 0 15mm 57 150Hz 2 0G 40minutes each inX Y and Zdirections JISC6...

Page 3: ...EQ P Pluscommon ofequaloutput Connectthepositivesideof externalpowersupply EQ Countequaloutput General purpose output EQ N Negative commonof equaloutput Connectthenegativesideof externalpowersupply Supportcable AWG28 16 Cable lengthshouldsatisfy thepowerspecification including thecablevoltagedrop EXT CTRL Signal name Function GND Ground ofexternal samplingstart stop clocksignal CLK Externalsamplin...

Page 4: ...snotconnected Setting Switches There are two setting switches x16 and x1 represent high bits and low bits of Module ID respectively Factorysettings 00 can be used when only one device per model is connectedto one computer Each device should be assigned a unique Module ID in the range of 00 7Fh when several devices with the same model are being connected ModuleID x16 0 ModuleID Settingdescription 0...

Page 5: ...r equivalent strip off the end of the cable and insert it to the connector plug then secure the cable bytighteningthe screws Likewise when connectingthe FG pin to the ground earth strip off the end of the cable and insert it to the connector plug then secure the cable bytighteningthe screws If you use thisproductin anoisy environment connecttheFGpinof theproductto the ground earth to stabilize the...

Reviews: