Function Specifications <2/2> 

Item 

Specification 

Output *1 

  Control 

  Control output signal type 

Optocoupler isolated open collector output 

Control output channel 

1 x 4 channels 

Control output signal 

- Count match 0 output(one-shot pulse output) 
- Count match 1 output(one-shot pulse output) 
- Digital filter error output(one-shot pulse output) 
- Abnormal input error output(one-shot pulse output) 
- General-purpose output(Level output) 
Software-selected from among the above five options 
(Positive/negative logic is selected with the software.) 

One shot output signal 
amplitude 

Selected between 10µsec, 100µsec, 1msec, 10msec and 100 msec 
(Can be set for each channel, within pre 1µsec) 

Response time 

5µsec (Max.) 

Output rating 

35VDC, 50mA(MAX) 

External Power 

5V - 12VDC±10% 

USB 

  Bus specification 

USB Specification 2.0/1.1-compliant 

USB transfer rate *2 

12Mbps (Full-speed), 480Mbps (High-speed)  

USB connector 

USB mini B connector 

Power supply 

Self-power 

Power supply 

  Input voltage range 

12 - 24VDC±10% 

Current consumption (Max.) 

12VDC 200mA, 24VDC 90mA 

Power supply connector 

European type terminal 3.5mm pitch 3-pin jack connector 

Common section 

  Interface connector 

Counter and Control :   European type terminal 3.5mm pitch   
 

8-pin jack connector x4 

Sampling :   

European type terminal 3.5mm pitch   

 

4-pin jack connector x1 

Dielectric strength 

1000VAC 

Physical dimensions (mm) 

188.0(W)×78.0(D)×30.5(H) (No projection included) 

Weight 

250g (Not including the USB cable, attachment, connector) 

The length of cable (supplied) 

USB cable(Type A - mini-B type) 1.8m 

 

*1  Use the shielded cable for this product to meet “CE EMC Directive”. 
*2  The USB transfer speed depends on the host PC environment used (OS and USB host controller). 

 
 

Installation Environment Requirements 

Item 

Specification 

Operating ambient temperature 

-20 - +60°C *1 

Operating ambient humidity 

10 - 90%RH (No condensation) 

Floating dust particles 

Not to be excessive 

Corrosive gases 

None 

Line-noise 
resistance    *2 

Line noise 

AC Line/±2kV   
Signal Line /±1kV(IEC61000-4-4 Level 3, EN61000-4-4 Level 3) 

Static 
electricity 
resistance 

Touch /±4kV(IEC61000-4-2 Level 2, EN61000-4-2 Level 2) 
Air /±8kV(IEC61000-4-2 Level 3, EN61000-4-2 Level 3) 

Vibration 
resistance 

Sweep 
resistance 

10 - 57Hz /semi-amplitude vibration 0.15mm, 57 - 150Hz/2.0G 
40minutes each in X, Y, and Z directions   
(JIS C60068-2-6-compliant, IEC60068-2-6-compliant) 

Shock resistance 

147m/s

2

(15G)/11ms/half-sine shock 

(JIS C 60068-2-27 -compliant, IEC 60068-2-27 -compliant) 

Standard 

VCCI Class A, FCC Class A, 
CE Marking (EMC Directive Class A, RoHS Directive) 

 

*1  When using the supplied AC adaptor POA 201-10-2, it is 0 - 40°C. 
*2  When using the supplied AC adaptor POA 201-10-2. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

AC adapter environmental condition (environmental specification) 

Item 

Specifications 

Input voltage range 

90 - 264VAC 

Rated input current 

300mA 

Number of frequency 

50 - 60Hz 

Rated output voltage 

12.0VDC 

Rated output current 

1.0A (Max.) 

Physical dimensions (mm) 

47.5(W)x75(D)x27.3(H) (No protrusions) 

Weight 

175g 

Operating temperature 

0 - 40ºC 

Operating humidity 

20 - 80%RH (No condensation) 

Life expectancy *1 

1.5 years (at the ambient temperature 40 ºC when 100VAC is 
input and 1.0A is output) 
4 years (at the ambient temperature 40 ºC when 100VAC is 
input and 0.5A is output) 

Allowable time of short interruption 

20ms (Max.) (When 100VAC is input and 0.55A is output) *2 

Floating dust particles 

Not to be excessive 

Corrosive gases 

None 

Voltage compatible to the supplied AC cable 

125VAC 7A 

 

*1  Life expectancy is four years when using this product. 
*2  When short interruption occurs and 

 
 

 

Physical Dimensions 

 

Product 

 

 

Physical dimensions of the supplied AC adapter (POA201-10-2) 

 

 
 

 

Packing List

 

 

Product…1 

Interface Connector(8-pin)…4 

Setup Guide…1 

Interface Connector(4-pin)…1 

Warranty Certificate…1 

Rubber feet…4 

Serial Number Label…1 

AC Adapter…1 

USB Cable (1.8m)…1 

AC Cable…1 

USB Cable Attachment on the main unit’s side)…1 

 

 

 

PLUG-IN Electronic GmbH  •  Am Sonnenlicht 5  •  82239 Alling  •  Tel.: +49 (0) 8141 3697-0  •  [email protected]  •  www.plug-in.de

Summary of Contents for CNT-3204IN-USB

Page 1: ...ing with magnet rubber feet etc In addition DIN rail mountingmechanism is equipped as standard with the product making it easyto install the product within the panel or the device Easy to wire terminal connector adopted Adoption of terminal connector with screws enables to achieve easy wiring Windowscompatible driver software Usingthe counter input driver API CNT WDM for USB makes it possible to c...

Page 2: ...s Nottobe excessive Corrosivegases None Line noise resistance 2 Line noise ACLine 2kV SignalLine 1kV IEC61000 4 4Level 3 EN61000 4 4Level 3 Static electricity resistance Touch 4kV IEC61000 4 2Level 2 EN61000 4 2Level 2 Air 8kV IEC61000 4 2Level 3 EN61000 4 2Level 3 Vibration resistance Sweep resistance 10 57Hz semi amplitude vibration 0 15mm 57 150Hz 2 0G 40minutes each inX Y and Zdirections JISC6...

Page 3: ...EQ P Pluscommon ofequaloutput Connectthepositivesideof externalpowersupply EQ Countequaloutput General purpose output EQ N Negative commonof equaloutput Connectthenegativesideof externalpowersupply Supportcable AWG28 16 Cable lengthshouldsatisfy thepowerspecification including thecablevoltagedrop EXT CTRL Signal name Function GND Ground ofexternal samplingstart stop clocksignal CLK Externalsamplin...

Page 4: ...snotconnected Setting Switches There are two setting switches x16 and x1 represent high bits and low bits of Module ID respectively Factorysettings 00 can be used when only one device per model is connectedto one computer Each device should be assigned a unique Module ID in the range of 00 7Fh when several devices with the same model are being connected ModuleID x16 0 ModuleID Settingdescription 0...

Page 5: ...r equivalent strip off the end of the cable and insert it to the connector plug then secure the cable bytighteningthe screws Likewise when connectingthe FG pin to the ground earth strip off the end of the cable and insert it to the connector plug then secure the cable bytighteningthe screws If you use thisproductin anoisy environment connecttheFGpinof theproductto the ground earth to stabilize the...

Reviews: