11
5201088 Rev. C
MCM 30 Electrostatic Charging Generator
STATUS –
Yellow LED indicates when the MCM 30 is in setup mode or indicates when
the MODE / SETUP button is pressed.
HV OUTPUT –
Green LED that illuminates when there is high voltage present on the HV
connector.
POWER –
Green LED that illuminates when the power switch is on and 24 VDC is applied.
BASIC OPERATION –
make all connection per section 4, (Installation) of this manual.
1. Install and mount the charging applicator to the MCM 30.
2. Refer to section 5 (Operation) MODE / SETUP of this manual to select the
operating mode and output level.
3. Set the operating Mode, (Voltage or Current), while using the Settings knob adjust
the output of the MCM 30 until the desired pinning is achieved.
4. Save this setting to the flash memory per the MODE / SETUP procedure in this
manual.
5. The MCM 30 is now ready for service.
NOTE -
In setting the output in Current Mode the pinning applicator should be
adjusted so as to limit the output voltage to approximately 24KV. This will allow
the MCM 30 to automatically adjust the output voltage, (up to 30KV), to
compensate for atmospheric changes and contamination.
6. MAINTENANCE
Cleaning
CAUTION!
Disconnect the electrostatic charging generator before attempting any
cleaning operation.
The exterior surface of the MCM 30 charging generator can be cleaned with a soft cloth
moistened with common window cleaning solution. Alcohols or solvent-based cleaners
must not be used.
NOTE -
The charging generator enclosure is not liquid tight and must not be
subjected to aerosol sprays or condensation, as damage to the internal circuitry
may occur.