8
5201088 Rev. C
MCM 30 Electrostatic Charging Generator
NOTE -
Fault Relay K1 is of the electro-mechanical type having a DC coil which
pulls down an armature which switches the contacts. Contact rating on the relay
is 24 VDC, 2 amps. See the following schematic diagram.
Position 3
Normally Closed (NC)
Positon 5
Normally Open (NO)
Position 4
Common (COM)
K1
SPST
Relay
Dry Contacts
MCM 30 in
Fault Alarm
or
Power Off
K1
SPST
Relay
Dry Contacts
MCM 30 in
Normal Operation
with
Power On
Position 3
Normally Closed (NC)
Positon 5
Normally Open (NO)
Position 4
Common (COM)
Fault Relay Schematic: example relay operation K1 inside MCM 30
NOTE -
Verify that the mounting and connections of the MCM 30 charging
generator and charging devices are properly installed prior to turning on the
equipment.