12
5201088 Rev. C
MCM 30 Electrostatic Charging Generator
7. TROUBLESHOOTING
This information provides a quick troubleshooting reference for the MCM 30 charging generator.
Should any of these possible solutions not solve the problem, please contact Simco-Ion Customer
Service.
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
MCM 30 FAILS TO OPERATE
(GREEN INDICATOR OFF)
AC ADAPTER NOT
CONNECTED
CHECK ALL ELECTRICAL
CONNECTIONS
REPLACE AC ADAPTER
AC ADAPTER DEFECTIVE
MCM 30 FAILS TO OPERATE
CHARGING DEVICE
(GREEN INDICATOR ON)
CHARGING DEVICE
CONNECTIONS LOOSE
TIGHTEN CHARGING DEVICE
CONNECTORS INTO POWER
SUPPLY
MCM 30 INDICATES FAULT
(RED INDICATOR ON)
CHARGING DEVICE DIRTY OR
DEFECTIVE
CLEAN OR REPLACE
CHARGING DEVICE
CHECK CHARGING DEVICE
CLEARANCES
CHARGING DEVICE SHORTED