19
IQ POWER MPS POWER SUPPLY
5201279 Rev A
5. OPERATION
NOTE
– Before switching on power supply; ensure units are properly
grounded and static bar & sensor bar are properly installed.
Power Supply Indicators
Power
: Lights (green) to indicate power is on and the IQ Power system is ready to
operate.
Flashes (green) to indicate power is on and MPS is in the Standby Mode.
Fault
: Lights (red) to indicate faulty condition of static bar, power supply or high
voltage connections. Power will have to be turned off to clear the fault.
When fault is cleared and power is restored, the fault light will remain off.
Flashes (red) to indicate a communication failure with Control Station
Power Supply Operators
Power Switch
: A slide switch to turn unit on and off when connected to an AC
adapter or if user power is applied through the 5-position terminal block.
The power switch is bypassed when power is applied through the M12 connector
(from the Control Station). In this case, the MPS will energize as soon as the
Control Station is turned on.
System Start-up
A. Apply line voltage to the AC adapter or switch on the Control Station.
B. Move the power supply “Power” switch to the “On” (1) position (not necessary
if using Control Station).
C. The power supply indicators will briefly self-test during which all will light.
D. After the self-test, the Fault light will extinguish and the Power light will remain
lit if the system is operating correctly.
On new systems the Ion Output parameter in the Control Station interface will
display low output, calibration must be performed.
NOTE
– Calibration should be performed when the system is first installed
and may be performed after the static bar has been cleaned and the system
verified as operating correctly.
E. If the system is new; perform an initial calibration (with Control Station only).
The initial calibration sets the relative nominal ion output for the system.
Calibration should only be performed on IQ Power systems that are new or just
cleaned and known to be in proper working order.