14
IQ POWER MPS POWER SUPPLY
5201279 Rev A
If multiple IQ Power / IQ Easy static neutralizer devices are connected to the
Control Station, each device must have a unique Power Supply Number (address
/ device number). This is necessary to enable reliable digital communication.
The Control Station can be used to automatically address the power supplies.
The default Power Supply Number for a new unit is “1”. Start the process with
non-MPS devices (IQ Power BPS and IQ Easy first), connect all non-MPS
devices, then finish the process with IQ Power MPS units. Plug the first power
supply (only) into the Control Station and turn the Control Station on. Allow
the Control Station to boot-up and begin operation. Plug the second power
supply into the Control Station. The Control Station will re-address the second
power supply to “2”. Plug the third power supply into the Control Station.
The Control Station will re-address the third power supply to “3”. Repeat this
process until all power supplies (or IQ Power / IQ Easy devices) are installed.
Each power supply or device will be given a unique address (device number).
C.
Connect user supplied power
(if used). In cases where the user does not want to
use the AC adapter but wants to supply 24 VDC power to the IQ Power MPS,
user supplied 24 VDC power may be applied via the 5-position terminal block.
The 5-position connector uses a Phoenix 1803604 terminal block. The
terminal block accepts 16-26 AWG solid or stranded wire with a strip length of
¼” [7mm]. To install wires into the connector, push the stripped wire fully into
the square hole on the connector and tighten securely with a small flat-blade
screwdriver.
To supply power through the 5-position terminal block, connect:
• +24 VDC to position 1
• 0V (ground) to position 2
The return / common MUST be bonded to electrical ground.
Wired in this fashion, the “Power” switch on the MPS face is in-circuit.
Power supplied in the above fashion must have adequate current available
to power the MPS power supply (1A minimum). Input power should be
appropriately fused for safety purposes.
See 5-Position Terminal Block diagram.
D.
Connect static bar
by plugging in high voltage connector on static bar cable
to HV connector on power supply. Secure high voltage connector with the (2)
captive screws on the sides of the connector. Do not over-tighten.
See Bar and Power Supply Connections diagram.
CAUTION – Electrical Shock Hazard
Do not connect static neutralizing bar with power supply energized. Switch
power off before connecting static bar.