11
IQ POWER MPS POWER SUPPLY
5201279 Rev A
Position
Description
1
MPS Power Connection, +24 VDC
2
MPS Power Connection, 0 VDC (ground). This position must be grounded. Also serves
Standby function.
3
MPS Output, negative connection, opto-isolated transistor *
4
MPS Output, positive connection, opto-isolated transistor *
5
MPS Standby, input connection, works in conjunction with position 2 (ground).
* Vceo (collector to emitter voltage) 40V max, Veco (emitter to collector voltage) 6V max, Ic (collector
current) 100 mA max.
Figure 9. IQ Power MPS 5-Position Terminal Block
Initial Considerations
Installation starts with mounting of the static neutralizing bar. Static bars are
typically installed just ahead of where problems due to static are occurring. The
power supply is installed in a convenient location within reach of the static bar
high voltage cable (standard length 3m [10 ft]) and visible to the machine operator.
Control station (where used) may be installed at any convenient location and
connected to the system using the pre-terminated M12 low voltage cable.