20
IQ POWER MPS POWER SUPPLY
5201279 Rev A
During calibration the target to be neutralized (web, film, etc.) may remain in
place, but MUST NOT BE MOVING. If the web is moving past the static bar
(e.g. the machine is in operation) the calibration may be faulty.
The system should be “on”. Access the IQ MPS Calibrate parameter on the
Control Station user interface device page. It may be necessary to tap on a tab
and/or the Page arrow to locate the Calibrate parameter. Tapping the pencil
icon next to Calibrate will open a prompt for a password. The default password
for set-up is “PASSWORD”. Follow the directions on the Control Station to
initiate the calibration sequence and set the relative nominal ion output for the
system.
During calibration the system output will be cycled and the indicator lights on
the MPS will flash. At completion of calibration the Power light will flicker.
The indicated ion output at the Control Station will be high (90-100%). The
calibration sequence takes approximately five seconds.
The calibration data is stored in non-volatile memory in the MPS and is used
on subsequent power ups.
Static Bar Operation
A. Operation normally requires only occasional checking of the system indicators
on the power supply.
B. Anticipated changes in the system indicators include a reduction of output over
time. This may occur over several weeks and ultimately cause the “Clean Bar”
icon to display on the Control Station. Regular maintenance will typically
prevent activation of the indicator.
C. Unanticipated changes in the system indicators include activation of the Fault
indicator. This would indicate faulty condition of static bar, power supply or
high voltage connections. See Troubleshooting section.
System Operation (with IQ Power Control Station)
The operation of the IQ Power MPS Power Supply can be controlled through the
IQ Power Control Station. In operation, a device icon appears on the Control
Station Home Page. Tapping on the device icon opens a Summary page containing
information about the MPS, static neutralizing bar, and static sensor bar (if paired).
More detailed information and user editable parameters are available through device
tabs. For information on these details see the Set Up (with IQ Power Control