UFD Applicator, Manual 40-43, Rev. 6.16
Section 1, 24 VDC MAC solenoid valve, 4 way, 02, 1/8 NPT, PN 100054
Description
Direct acting poppet valve, 4-way, 1/8 NPT ports, with non-locking recessed manual
operator.
Connections
IN
Inlet
EX
Exhaust
A
Open side of module
B
Close side of module
Typical Setup
Apply full air pressure (80-90 psi / 5.5-6.2 bar) to IN port of solenoid valve. Use air control
kit PN 100055, configured as shown below.
Schematic:
Solenoid valve supplied with Applicator.
PN 100055 Air Control Kit
configured for use with
conventional solenoid valve.