1
1. General description
The access controller, CCA, allows the opening of all types of door openers once an authorized RFID card has been
read. The reading is performed by an external reader connected to the controller (Ref. LCA). The controller is
compatible with several input voltages. It allows to control the voltage pass that feeds the current lock or use the
power supply of the controller to power the lock. Thanks to all these compatibilities the controller can be coupled
to existing systems or installed in new scenarios.
The programming of user cards can be done through the use of other cards (called master) or through a remote
control. It is important to note that, through remote control, other functions can be performed such as setting the
opening time, deleting and registering cards selectively, activating or deactivating the sound or LED indicators, ...
Master cards provide simplicity when registering user cards.
There is no distinction between cards except their programming; For example, a master card could be
programmed as a user card. As explained below, it is important to identify each user card with an identifying
number.
•
It allows to feed several types of lock (AC / DC) with the own voltage that feeds the controller
•
It allows to control the voltage that feeds the lock from an external source, either AC or DC
•
Allows the connection of a button (push button) for instant door opening
•
Users registered in a controller can be cloned in other controllers
•
Supports up to 1000 users
•
Compatible with Wiegand readers
•
Allows management by remote control
2. Accessories
•
1x Remote control (keyboard)
•
1x Master card to add users
•
1x Master card to remove users
•
1x Configuration jumper
•
1x Protection diode
•
1x Screwdriver
•
2x Anchors and screws
•
1x Installation Manual
3. Connections and indicators
Signal
Terminal
strip
Type
Description
BUZZER
Left
Output
Tone indicator to the card reader
LED
Output
Led indicator of the card reader
D0
Entrada
Data[0] reception from the card reader
D1
Entrada
Data[1] reception from the card reader
GND
Entrada / Output
Ground (Connection to the card reader)
GND
Entrada / Output
Ground (DC Voltage feeding)
AC / DC +
Entrada
Common connector for AC or DC power (positive)
AC
Entrada
Connector for AC voltage feeding
OPEN
Right
Entrada
Connect to the external push button (Optional)
NO
Output
Relay output (Normally open)
COM
Output
In "Dry Contact" configuration (Position A): Common Port
In "DC Out" configuration (Position B): Ground
Connect to external push button (optional)
NC
Output
Relay output (Normally closed)
V OUT
Output
Voltage for feeding the card reader
IR
Input
IR sensor for remote control
Output
Status LED indicator