3
A-Position (Dry contact)
B-Position (Input pass)
Terminals
COM-NC
COM-NO
COM-NC
COM-NO
Stand-by
Short circuit
Open circuit
Same voltage as
in the input
0V
Opening
Open circuit
Short circuit
0V
Same voltage as
in the input
Open the device and adjust the jumpers depending on your needs.
Attention: Install the supplied diode directly in the
door opener in the case that it supplies the lock with
direct voltage -DC.
Do not use the diode in case of powering the system
in AC. Respect the polarity of the diode as indicated:
5. Installation
Below there are two typical installations with their connection and configuration:
Configuration in “Input Pass” (the same voltage
that feeds the controller, will feed the lock).
Configuration in dry contact (the lock opens as the
controller opens or closes; The controller acts as
a switch).