background image

 

 

 

Step 1 

Power off the controller 

 

Step 2 

Make a short circuit between GND and OPEN.  

Otherwise, should a push button be connected (for opening 

purposes), keep it pressed.  

 

Step 3 

Power on the system again 

Two sounds will be heard 
and the LED will change its 
colour 

 

Present the two cards on the card reader. The first will be 

coded as “MASTER ADD” (For subscribing). The second, 

will be “MASTER DELTE” (For unsubscribing).  

After each card 
presentation, a single 
sound will be heard. After 
presenting the second card,  
the system will enter in 
stand-by mode.  
If any card is presented 
within 10 seconds, the 
system will enter in stand-
by mode.  

Step 4 

Remove the bridge 

 

 
 

6.3.2. Management of user cards using master cards 
 

Subscribing: 
 

Step 1 

Sweep MASTER ADD card 

 

Step 2 

Sweep the user card 

More user cards may be swept (A sound will 

be heard) 

Step 3 

Sweep MASTER ADD card 

 

 
Unsubscribing:  
 

Step 1 

Sweep MASTER DELTE card 

 

Step 2 

Sweep the user card 

More user cards may be swept (A sound will 

be heard) 

Step 3 

Sweep MASTER DELETE card 

 

 

 

6.4. Restore to factory default values 
The following process restores the original default factory values. Registered user cards, are NOT lost. Registered  
master cards, yes. Other values are set back to factory default. 
 

 

 

Step 1 

Power off the controller 

 

Step 2 

Make a short circuit between GND and OPEN.  

Otherwise, should a push button be connected (for opening 

purposes), keep it pressed.  

 

Step 3 

Power on the system again 

Two sounds will be heard 
and the LED will change its 
colour 

Step 4 

Keep the short circuit for at least 10 seconds.  

A sound will be Heard and 

will enter in stand-by mode. 

(Red LED) 

 

 
 

 

 

Summary of Contents for EKSELANS 370001

Page 1: ...CCA 370001 Access controller EN Installation manual ...

Page 2: ... controller It allows to control the voltage that feeds the lock from an external source either AC or DC Allows the connection of a button push button for instant door opening Users registered in a controller can be cloned in other controllers Supports up to 1000 users Compatible with Wiegand readers Allows management by remote control 2 Accessories 1x Remote control keyboard 1x Master card to add...

Page 3: ... DC voltage In case of powering the controller with alternating current connect the source to the terminals indicated as AC and AC In case of powering the controller with direct current connect the source to the terminals indicated as GND and DC Respect the polarity Check the maximum rating voltage in the technical specification 4 2 Door opener voltage feeding The controller may act on the door op...

Page 4: ... supplied diode directly in the door opener in the case that it supplies the lock with direct voltage DC Do not use the diode in case of powering the system in AC Respect the polarity of the diode as indicated 5 Installation Below there are two typical installations with their connection and configuration Configuration in Input Pass the same voltage that feeds the controller will feed the lock Con...

Page 5: ...With the remote control you can force a card to have a specific identifier leaving bubbles if desired There cannot be two user cards with the same identifier It is recommended to register the identifier by relating it to the serial number of the card and to the user of the card It is not recommended to write down the identifier on the card itself Should it be lost the identifier to be removed from...

Page 6: ...elete a user card by reading it with the card reader Not lost card Step 1 Enter in the programming mode Master code Step 2 Sweep the card to be unsubscribed This position will be empty 2 Sweep card Step 3 Exit the programming mode Note that a bubble can be been created There can be an empty identifier position not linked with a user card To delete a user card from a specific position The card is l...

Page 7: ...the programming mode Master code Step 2 Start the transfer 9 6 Step 3 Wait until the transmission ends The green LED blinks Step 4 Exit the programming mode Note that Both units must have the same master code A cloning process with 1000 registered users may last up to 3 minutes Check connections Avoid short circuits 6 3 Programming via master cards By using the master cards it is possible to subsc...

Page 8: ...s Subscribing Step 1 Sweep MASTER ADD card Step 2 Sweep the user card More user cards may be swept A sound will be heard Step 3 Sweep MASTER ADD card Unsubscribing Step 1 Sweep MASTER DELTE card Step 2 Sweep the user card More user cards may be swept A sound will be heard Step 3 Sweep MASTER DELETE card 6 4 Restore to factory default values The following process restores the original default facto...

Page 9: ...minal AC V rms 12 30 24 DC Vdc 9 24 12 Consumption Stand by Maximum AC mA rms 115 170 DC mA 60 80 Output voltage For LCA Vdc 12 Maximum switching current A 1 Maximum distance IR Keyboard m 10 Working temperatura ºC 40 60 Working humidity Hum 0 90 Dimensions mm 90 x 63 x 22 Including reader excluding door opener Depending on Ilumination battery ...

Reviews: