5
6.2.2. User management (via remote control)
Each user card is registered with an identifier that matches its position within the system.
The controller can assign auto-incremented identifiers. You can also assign a specific identifier.
Subscribing:
To add user cards at a position given by the system:
Step 1
Enter in the programming mode
* <Master code> #
Step 2
Pass the card through the reader and
press #. Repeat this step if several cards
need to be registered
1 <Sweep card > #
Step 3
Exit the programming mode
*
Remember that in the case there are empty positions not assigned to a card (Bubbles), this process will assign to
the card registered the first available position/identifier. A bubble will appear when a specific card (Not the last
one) has been removed.
To add user cards in a particular position:
Step 1
Enter in the programming mode
* <Master code> #
Step 2
Insert the desired identifier and sweep the
card
1 <Desired identifier> # <Sweep card> #
Where <Desired identifier> is a number
from 1 to 999. Do not insert 00x. Insert x
directly.
Step 3
Exit the programming mode
*
Unsubscribing:
To delete a user card by reading it with the card reader (Not lost card):
Step 1
Enter in the programming mode
* <Master code> #
Step 2
Sweep the card to be unsubscribed. This
position will be empty
2 <Sweep card> #
Step 3
Exit the programming mode
*
Note that a bubble can be been created. There can be an empty identifier position not linked with a
user card.
To delete a user card from a specific position (The card is lost):
Step 1
Enter in the programming mode
* <Master code> #
Step 2
Insert the identifier position to be deleted.
This position will be deleted.
2 <Identifier> #
Where <Identifier> is a number from 1 to
999. Do not insert 00x. Insert x directy.
Step 3
Exit the programming mode
*
Note that a bubble can be been created. There can be an empty identifier position not linked with a
user card.
To delete all user cards in the system:
Step 1
Enter in the programming mode
* <Master code> #
Step 2
2 <Master code> #
Step 3
Exit the programming mode
*
6.2.3. Relay configuration (via remote control)
The opening time can be adjusted as wished in a range from 1 to 99 seconds. Its default value is 5 seconds.
Step 1
Enter in the programming mode
* <Master code> #
Step 2
Insert two digits that indicate the number
of seconds that open the relay.
3 (1~99)#
Example: Insert <310#> for 10 seconds.
Step 3
Exit the programming mode
*