Installation and Operation Guide
3-18
Operation
Command
Default
Enter the programming mode
*900 +XXXX
where:
XXXX=Password
1234
Exit the programming mode
*900
Maximum number of digits to be dialed.
Less than XX: 3-second timeout, before dialing
starts.
Exactly XX digits dialed: Number dialed directly.
More than XX digits dialed: Number will be cut
off after reaching XX.
*300 + XX
where:
XX = 01-32 (digits)
10 towards PBX.
(Tip: set the
default to
country’s max.
telephone
number length).
Reverse polarity. The CGW-D can be
programmed to send a “reverse polarity”
command to the PBX, when a “call answer” is
detected. This parameter is useful if call
accounting software is active.
*320 + X
where:
X = 0 – 2 (3 in 4_14 Partner)
0 = No reverse polarity
1 = Reverse polarity only on outgoing
calls
2 = Reverse polarity for incoming and
outgoing calls
2
Output volume control
*330 + X where:
X = 1-9 (9 is highest)
5
End dialing digit definition
*334 + X
where X – DTMF digit 0-9,*,#
None
Hook Flash time in msec with option to set
040-980 in 20 msec steps.
*370 + XXX
300 ms
Pulse drop (Loop disconnect) duration.
The length of the loop current disconnection to
indicate to the FXS direction about the
conversation end.
*380 + XX
where:
XX = number of 1/10sec
XX = 01-19
08 = 800 msec
Conversation timeout. The telephone
conversation will be automatically terminated
after this timeout.
*390 + XX
where:
XX = time out in [minutes]01-99
00 = unlimited
00 (unlimited)
First digit dialing timeout. During this time
interval the gateway waits for the first dialed
digit.
*391 + XX,
where XX – time in seconds 03-60
10
Inter digit timeout. Maximum available time
interval between dialed digits
*392 + X
where: XX – time in seconds 2-9
3
Summary of Contents for CGW-D
Page 1: ...CGW D June2008 Installation and Operation Guide Version 2 Release 4...
Page 3: ......
Page 7: ...Installation and Operation Guide iv...
Page 13: ...Installation and Operation Guide 1 6 This page is intentionally left blank...
Page 40: ...CGW D 3 15 Figure 3 19 Edit User Window Figure 3 20 Prefix Restriction Numbers Window...
Page 47: ...Installation and Operation Guide 3 22...
Page 55: ...Installation and Operation Guide 4 8 This page is left intentionally blank...
Page 59: ...Installation and Operation Guide 6 2 This page is intentionally left blank...