Installation and Operation Guide
3-12
Item
Function
Default
Range/
Option
Outgoing Calls
Gateway sends reverse polarity to the FXS side
when a call disconnection was received from the
cellular network during outgoing calls only.
Deselected
Outgoing
Calls
All Calls
Gateway sends reverse polarity to the FXS side
when a call disconnection was received from the
cellular network during all calls.
Selected
All Calls
Disconnection – Pulse Drop
Enabled
Activates pulse drop (loop current disconnection)
service and enables the Loop Disconnect Time
field.
Selected
Loop Disconnect
Time
Contains a value in msec for pulse interval that
informs the PBX of call disconnection.
100
100-1900
msec
Date & Time
Displays current date and time
APPLY
Applies all changes.
3.2.2.3
Tones Parameters Tab
The
Tones Parameters
tab (Figure
3-17
) contains the options for tone parameters configuration.
Figure
3-17. Tones Parameters Tab