CGW-D
3-17
Subscriber’s Timer
Reset Day in
Month
Contains a value that defines the day of the
month in which the subscriber’s timer will be
reset.
1
1-28
Call Back/Through
First Digit Timeout
Operation
Enables to select the action that gateway will
perform if the caller starts dialing after the
First
digit timeout
parameter defined in the
Dialing
Parameters
window has elapsed.
When this occurs, the gateway will either
disconnect the call or forward it to the FXS
direction.
Disconnect
Disconnect
FW to
Phone
Call Divert
Number
Enables to divert the call to an alternate cellular
gateway. A number in the field enables this
feature; an empty field disables this feature.
Empty
APPLY
Applies all changes.
3.2.3
DTMF Programming
The CGW- D device can be programmed using DTMF commands. To program the unit, perform the
steps as follows:
1.
If the unit is connected to a PBX, remove the cable from the FXO connector on the unit front
panel.
2.
Connect an analog telephone directly to the FXO connector.
3.
Dial *900 and enter the password (1234 by default).
4.
Use the commands in the following table for programming.
When DTMF programming changes are made, the device will perform an automatic
reset for the changes to take effect.
Exit from the programming mode by *900 or hanging up the telephone.
If you do not enter digits for 45 seconds, the unit will automatically exit the
programming mode.
When entering a correct command, you will hear two beeps; when entering an
incorrect command, you will hear long a beep.
Summary of Contents for CGW-D
Page 1: ...CGW D June2008 Installation and Operation Guide Version 2 Release 4...
Page 3: ......
Page 7: ...Installation and Operation Guide iv...
Page 13: ...Installation and Operation Guide 1 6 This page is intentionally left blank...
Page 40: ...CGW D 3 15 Figure 3 19 Edit User Window Figure 3 20 Prefix Restriction Numbers Window...
Page 47: ...Installation and Operation Guide 3 22...
Page 55: ...Installation and Operation Guide 4 8 This page is left intentionally blank...
Page 59: ...Installation and Operation Guide 6 2 This page is intentionally left blank...