TDC-0951-005 100W-R and 100WP-R Datalogging ERT Module Installation Guide
11
Proprietary and Confidential
Install the 100W-R and 100WP-R ERT modules using one of the following mounting options:
100W-R and 100WP-R ERT modules Mounting Options
Pipe Mount
The ERT module mounts to a pipe near the meter (see
Pipe Mount Installation
). This option requires
the Remote Mount Kit and the appropriate Pipe Mount Kit.
Remote Mount
The ERT module mounts to a flat surface and connects to the meter register with a cable up to 300 feet
(see
Remote Mount Installation
). This option requires the Remote Mount Kit.
Direct Meter Register
Mount
The ERT module mounts directly to a meter register designed for ERT module direct mounting. This
installation does not require a mounting kit (see
Direct-Mounting to the Meter Register
on page 29).
100W-R and 100WP-R ERT Module Accessories
100W-R/100WP-R Mounting Accessories
Accessory
Part Number
Remote Mount Kit (Encoder/Pulser only)
CFG-0771-021
Remote Mount Kit (Encoder/Pulser with Leak Sensor)
CFG-1300-003
Pipe Mount Kit
pipes from 3/4 to 1 3/4 inches
pipes from 1 5/16 to 2 1/4 inches
pipes up to 4 inches
CFG-0217-503
CFG-0217-504
CFG-0217-501
Direct Mount Screw Pack
Bulk
80 per bag
122 per bag
SCR-0010-005
SCR-0010-004
SCR-0010-001
Installing 100W-R and 100WP-R Cable Strain Relief
After you complete the ERT module to register or ERT module to register and Leak Sensor connections (for
more information, see
Connecting the Leak Sensor to the 100W-R and 100WP-R ERT Modules
), install a
cable tie to the meter cable (and Leak Sensor cable, if applicable) just below the exposed colored lead wires
on the cable insulation. The cable tie performs as a cable strain relief to reduce the risk of destructive tension
on the lead wires.
C
H A P T E R
4
Installing the 100W-R and 100WP-R ERT Modules