![ITRON 100W-R Installation Manual Download Page 15](http://html1.mh-extra.com/html/itron/100w-r/100w-r_installation-manual_2095983015.webp)
Initializing, Programming, and Connecting the ERT Module
TDC-0951-005 100W-R and 100WP-R Datalogging ERT Module Installation Guide
10
Proprietary and Confidential
Connecting the 100WP-R to a Remote Meter Register
Connect the 100WP-R wires from the ERT module to the register screw terminals according to the following
table.
Register Manufacturer
100WP-R wire color
Brown
(signal)
Gray
(common)
Yellow
(tamper)
Register screw color designator
Elster Digital
BLK
GRN
R
Itron (Actaris) Cyble Sensor (2-
wire)
Either wire
Remaining wire must be connected to both
ERT module wires
Badger RTR
R
BLK
Green/bare
Elster V100
BLK
R
Blue
Sensus PMM
R
BLK
Bare
Connect the ERT module to the cable using gel-cap connectors (see
Using Gel Cap Connectors
on page 37).
Verifying 100W-R and 100WP-R ERT Module Operation
Use one of the following handheld computers to verify the ERT module is correctly recording consumption
data.
FC200SR
FC300 with SRead
Caution
Each handheld radio requires special setup and configuration parameters to
successfully read and program 100W modules. Refer to the respective meter
reading application for specific instructions.
Do not use ReadOne Pro, FS2PN and FS3PN, or FC200R handhelds to read the
100WP-R. These readers do not operate their receivers long enough or at the right
frequency to reliably capture a 100WP-R transmission.
Refer to the user guide for your programming device (see
Related Documents
on page 2) and data collection
application for more information.