Initializing, Programming, and Connecting the ERT Module
TDC-0951-005 100W-R and 100WP-R Datalogging ERT Module Installation Guide
8
Proprietary and Confidential
Programming the 100WP-R
Programming the 100WP-R requires one of the following handheld computers running Field Deployment
Manager (FDM) version 1.0 or later.
FC200SR handheld computer (Itron part number FC2-0005-004 or FC2-0006-004)
FC300 with SRead
For normal activation, connect the 100WP-R to the water meter register and program the ERT module with
FDM.
100WP-R Pulser Start-up
The 100WP-R enters run mode by completing programming with FDM. Programming sets the appropriate
pulser parameters (initial consumption and Utility ID).
Itron strongly recommends performing a
Check ERT
with a handheld computer running FDM to verify the
100WP-R is operating correctly after installation. Performing a
Check ERT
will:
Generate an immediate register read.
Align the 100WP-R's time with the handheld's time.
Important
Periodically dock or cradle the handheld computer or mobile reader to keep the time current.
Verify communication with the Leak Sensor.
Check for tamper flags.