Itowa TUNNER SETS User Manual Download Page 5

 

ItowaK 

    TUNNER SETS 

   

          

USER MANUAL 

 

      

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TUNNER SETS

Page 1: ...ItowaK USER MANUAL TUNNER SETS GCFI...

Page 2: ......

Page 3: ...UTHORISATION FROM ITOWA IN THE EVENT OF INFRINGEMENT ITOWA RESERVES THE RIGHT TO TAKE THE ACTION IT DEEMS NECESSARY IN ACCORDANCE WITH THE CURRENT LAW ITOWA RESEREVESTHERIGHTTOMODIFYTHISMANUALWITHOUTP...

Page 4: ...1 FASTENING OPTIONS 7 5 2 CONNECTING THE SET 8 5 3 POWERSUPPLYOFTHERECEIVER 8 5 4 START UP 8 5 4 1 SETTING THE TRANSMISSION TIME 8 5 4 2 BATTERY STATUS 9 6 MAINTENANCE OF THE RADIOCONTROL SET 9 6 1 MA...

Page 5: ...ItowaK TUNNER SETS USER MANUAL...

Page 6: ...ItowaK TUNNER SETS USER MANUAL FULLY CHARGE THE BATTERIES BEFORE USING THE SET FOR THE FIRST TIME...

Page 7: ...If this is not possible he should position himself where he can see as much of the manoeuvre as possible and coordinate with another person when he cannot see properly Never perform a manoeuvre which...

Page 8: ...rnatively 3 DESCRIPTION OF THE SET TRANSMITTER RECEIVER BATTERIES CHARGER 3 1 TRANSMITTER This is a sealed pushbutton box in highly resistant plastic material The manoeuvre pushbuttons and display led...

Page 9: ...noeuvre of the crane The signal received by the antenna is injected into the receiver which supplies a low frequency signal in FFSK code to the microprocessor The control module checks that the inform...

Page 10: ...play leds one for power supply indicating that the set is connected to the mains and the other indicating that the battery is being charged When the battery is inserted the charger tests its level and...

Page 11: ...SIVE EMERGENCY TIME 1900 ms RADIUS OF ACTION 90 metres Frequency bands 433 050 to 434 775 MHz I ETS 300 220 868 000 to 870 000 MHz TEMPERATURE RANGE From 20 C to 70 C Transmission power 10 mW P R A Po...

Page 12: ...cording to EN 60047 5 1 Max consumption 0 1 A 48 Vac 0 05 A 115 Vac 0 03 A 230 Vac 0 135 A 24 Vdc Connection By means of an Itowa 26 pin connector Fuses Emergency Stop Manoeuvre 3 A Dimensions Externa...

Page 13: ...antenna it should be free of metal shields in order to achieve a better radio link and avoid failures in communication 5 1 1 FASTENING OPTIONS Standard fixing 1 2 Optional fixing For the magnetic fas...

Page 14: ...STOP BUTTON and press the START button the remote control will start to operate by turning on the stop and start relays and the general contactor will be locked The led and the S1 led Start up led of...

Page 15: ...have purchased is manufactured using top quality materials to ensure perfect working order and operation of the remote control Similarly to all machinery and equipment the remote control requires mini...

Page 16: ...d passive safety circuits The correct working order of all the leds display messages The receiver cover and packing gland should be properly sealed The firm fastening of the whole unit If the antenna...

Page 17: ...ugh a number of flashes equal to this value starting with LED S1 with the first digit of the code reading from left to right The following table shows the correspondence between the hexadecimal value...

Page 18: ...check that all actuators of the transmitter are in the stand by position Led S4 of the RX flashes Eeprom fault Check in the RX that it is inserted in its housing If it is and still does not work conta...

Page 19: ...n of set for time or STOP BUTTON MODE S2 Stand by mode or manoeuvre without changes Fault in Stop relays Flash for each mode change in one of the relays MODE S3 MODE S4 E2p Ok Error in eeprom MODE Set...

Page 20: ...S MODE Transmitter on Communication between Tx Rx Together with led keypad Transmitter off MODE S1 E2prom error MODE S2 Manoeuvre button is on when start button is pressed MODE Standby mode or battery...

Page 21: ...anoeuvre does not require independent contacts a jumper should be made between terminals 23 and 25 and the manoeuvre in terminals 24 and 26 should be connected This relay can be configured as N C thro...

Page 22: ...nic waste separately means avoiding possible negative consequences on the environment and also the materials can be treated and recycled leading to significant saving in energy and resources To underl...

Page 23: ......

Reviews: