8. TROUBLESHOOTING
INCIDENT
SITUATION
ACTION
The set does not start
up
None of the transmitter
indicator
and
light up
Check that the battery is properly inserted.
Check that the battery is charged or directly
replace with a charged battery.
Both leds
and
of
the transmitter flash
Transmitter with keyboard is locked, follow steps
given in
“Locking the Keyboard”
to unlock it.
Only led S1 lights up
EEPROM error. Check in the transmitter that it is
inserted in its housing. If it is and still does not
work, contact the Technical Assistance Service.
Led S2 of the transmitter
lights up and flashes
A pushbutton is pressed, check that all actuators
of the transmitter are in the stand-by position.
Led S4 of the RX flashes
Eeprom fault. Check in the RX that it is inserted in
its housing. If it is and still does not work, contact
the Technical Assistance Service.
The set is not connected to
the machine
Connect the cable from the remote control to the
electric panel of the machine using the
corresponding connectors.
The set is connected to the
machine but it does not
work
The power supply of the set is under 45% of the
nominal value.
The set starts up but
the machine does
not work.
The set is connected to the
machine, but it still does not
work
The fuses of the stop relays are blown. They
should be replaced with new fuses of the same
value.
Place the pushbuttons of the cable/cabin instead
of the remote control. If it still does not work, the
problem is with the machine.