4.3. RECEIVER
Maximum number of
relay switchings:
Resistive load:
Inductive load (cosØ=0.4):
5 A at 250 Vac or 30 vdc
2 A at 250 Vac or 30 vdc
Power supply:
48 Vac / 115 / 230 Vac (-20% + 15%) according to EN 60047-5-1
24 Vdc (-20% + 15%) according to EN 60047-5-1
Max. consumption:
0.1 A (48 V
ac) / 0.05 A (115 Vac) / 0.03 A (230 Vac)
0.135 A (24 Vdc)
Connection:
By means of an Itowa 26-pin connector
Fuses:
Emergency Stop Manoeuvre 3 A
Dimensions:
External: 190 x 83 x 165 mm
Weight:
With fastening:
890 g.
Fastening:
With bolts, DIN rail or magnetic (optional)
Protection:
IP65
4.4. BATTERY CHARGER
Power supply:
115 / 230 Vac
– 15 Vdc (Max. 3 VA)
Charging time:
8
hours
Protection:
IP30
Charger Dimensions:
75 x 95 x 50 mm