background image

- 6 -

EASY MIX PLUS

Easy Mix Plus - 2018/07 - Rev. 03   

EN

CONVENTIONAL SYMBOLS

CAUTION: ELECTRIC SHOCK HAZARD

The staff involved is warned that the non-observance of safety rules in carrying out the operation 

described may cause an electric shock.

CAUTION: DANGER FROM HIGH TEMPERATURES

This warns the staff involved that failure to abide by safety rules in carrying out the operation 

described involves the risk of burns and scalds.

CAUTION CRUSHING HAZARD

This warns the staff involved that failure to abide by safety rules in carrying out the operation 

described involves the risk of suffering crushed fingers or hands.

CAUTION: GENERAL HAZARD

The staff involved is warned that the operation described may cause injury if not performed 

following safety rules.

NOTE

It points out significant information for the personnel involved.

WARNINGS

This warns the personnel involved that the non-observance of warnings may cause loss of data 

and damage to the machine, or cause risks for noncompliance with any applicable law/regulations

PERSONAL PROTECTION DEVICES

This symbol on the side means that the operator must use personal protection against an implicit 

risk of accident.

EQUIPOTENTIAL CONNECTION

For connecting all appliances with this type of connection.

Warning: do not connect to ground.

 

QUALIFICATION OF THE PERSONNEL SYMBOLS

The personnel allowed to operate the machine can be differentiated by the level of preparation 

and responsibility in:

OPERATOR

Unqualified personnel, without any specific technical abilities, capable of carrying out simple 

jobs, such as: operating the machine using the commands available on the keypad, the loading 

and unloading of products used during production, the loading of any consumable materials, basic 

maintenance operations, (cleaning, simple blockages, inspections of the instrumentation, etc.).

QUALIFIED ENGINEER

He/she is a skilled engineer, capable of operating the machine under normal conditions; he/she is 

able to carry out operations on mechanical parts and all adjustments, as well as maintenance and 

repairs. He/she is qualified for interventions on electrical and refrigeration components.

ICETEAM 1927 TECHNICIAN

He/she is a qualified engineer the manufacturer entrusted with complex operations under particular 

conditions or in accordance with agreements made with the machine's user.

Summary of Contents for ICETEAM EASY MIX 120 PLUS

Page 1: ...IX PLUS Code IC193 008613_03 Italian Gelato Concepts Pty Limited Unit 1 37 Mortimer Road Acacia Ridge Qld 4110 Bris Office 61 0 7 3162 7724 Syd Office 61 0 2 8311 9701 Email info italiangelato com au...

Page 2: ...egulation 2004 1935 EC relating to Materials and articles in contact with foodstuffs Regulation 2023 2006 EC Good manufacturing practice for materials and articles intended to come into contact with f...

Page 3: ...SPOSAL OF PACKAGING MATERIALS 11 1 7 WEEE Waste Electrical and Electronic Equipment 12 SEC 2 INSTALLATION 2 1 ROOM NECESSARY FOR MACHINE USE 13 2 2 WATER SUPPLY CONNECTION 13 2 3 MACHINES WITH AIR COO...

Page 4: ...5 4 HOW TO USE CLEANING SANITIZING SOLUTION 32 5 5 PRELIMINARY CLEANING 32 5 6 SPIGOT PISTON REMOVAL 32 5 7 DISASSEMBLY OF HOPPER LID 33 5 8 DISASSEMBLY OF BEATER EASY MIX 60 PLUS 33 5 9 DISASSEMBLY...

Page 5: ...Section A section is the part of the manual identifying a specific topic related to a machine part Chapter A chapter is that part of a section describing an assembly or concept relevant to a machine...

Page 6: ...is symbol on the side means that the operator must use personal protection against an implicit risk of accident EQUIPOTENTIAL CONNECTION For connecting all appliances with this type of connection Warn...

Page 7: ...IMPORTANT Make sure that the personnel do not perform operations out of their range of knowledge and responsibility refer to Qualification of the personnel symbols NOTE According to the standard in f...

Page 8: ...8 EASY MIX PLUS Easy Mix Plus 2018 07 Rev 03 EN...

Page 9: ...ration and requests of spare parts and service The manufacturer reserves the right to make any changes deemed necessary to the machine described in this manual without prior notice The descriptions an...

Page 10: ...anthesavingitself Bearing in mind the above statements please into consideration the following choose high quality natural ingredients and create your own mix or buy it from trustworthy suppliers clos...

Page 11: ...ubject to explosion proof laws its use is thus bound to complying rooms and normal atmosphere 1 4 NOISE The equivalent continuous A weighted sound pressure level in a workplace for water cooled as wel...

Page 12: ...e disposed of with normal urban waste Instead it is the user s responsibility to dispose of this product by returning it to a collection point designated for the recycling treatment of electrical and...

Page 13: ...chines with air cooled condenser must be installed at least 50 cm away from the back wall in order to allow free air circulation around the condenser Frequently clean the floor under and around the ma...

Page 14: ...he appliance must be installed according to the current regulations for electrical installation by competent and qualified technical personnel meeting the technical and professional requirements provi...

Page 15: ...p is necessary Gas filling necessary to the circuit is carried out at ICETEAM 1927 factory during the machine post production testing top ups or filling are not required if the machine is new If any g...

Page 16: ...16 EASY MIX PLUS Easy Mix Plus 2018 07 Rev 03 EN...

Page 17: ...to electrical equipment and machineries this appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge u...

Page 18: ...ng stage if no button is pressed for 3 minutes the display illumination willswitchoffandremaininstand by Toswitchthedisplayonagain pressanybutton STOP button In this function the machine is not workin...

Page 19: ...ine the timer countdown on the left on the second line and the temperature of the product inside hopper on the right Press Beating button to switch on beating and the following occurs beating LED stea...

Page 20: ...ttons select now one of the following 60 40 Full Filling 40 30 Half Filling Thecyclestartsautomaticallyafter3secondsoruponpressingtheAUTObuttonagain The machine starts to cool the product and the disp...

Page 21: ...cator located on the left of each push button switches on this means that the function corresponding to the symbol alongside the lit indicator itself has been switched on AUTO button When the AUTO but...

Page 22: ...second menu is displayed which allows the user to select the type of heating based on the product quantity in the hopper By using the Increase and Decrease buttons select now one of the following 120...

Page 23: ...and the display shall be as follows COOLING 04 C 85 C the current function on the first line on the second line the set temperature on the left the product temperature on the right and the temperatur...

Page 24: ...red cycle By pressing the AUTO button STOP asymix60plus a second menu will show up This will allow you to select the kind of operation you need in accordance with the product quantity inside the hoppe...

Page 25: ...aximum values shown in the table Sec 1 2 2 the hopper is provided with an inside graduation for an approximate indication of mix quantity contained see picture below Before pouring the mix make sure t...

Page 26: ...ease curve or the duration in case of a pause in the middle Beating can be modified Modifying the beating Press the Beating button Beating can be edited in High Speed clockwise rotation direction Beat...

Page 27: ...inutes day of week day of month month year language time ON Beat time OFF Beat timer Backlight Time ON Beat Withintermittentbeating thebeateroperatesforaprogrammabletimewhichisusually15seconds Time OF...

Page 28: ...28 EASY MIX PLUS Easy Mix Plus 2018 07 Rev 03 EN...

Page 29: ...y Beater Thermal Breaker tripping When the beater thermal breaker trips the machine enters STOP mode and the display reads Beater Thermal Breaker Alarm TER2 Easy mix 120 Plus only TER2 temperature pro...

Page 30: ...o in the heating phase when power is restored the machine resumes heating without displaying any message however saving the Black Out event o in the cooling phase after restoring the power supply the...

Page 31: ...ve detergent solution to wash the parts Manually wash the parts in water max 60 C using a non aggressive detergent and the cleaning brushes supplied as standard Use drinking water bacteriologically pu...

Page 32: ...off and STOP led on make sure that the mix dispensing spigot is closed pour water into the hopper according to the quantity necessary for cleaning the machine by pressing the shower push button and us...

Page 33: ...e lid by lifting it vertically and pushing it out of the fixed hinges Wash all removed parts using cleaning sanitizing solution and then rinse Refit the lid Remove the BEATER by pulling it gently upwa...

Page 34: ...ise and pulling it upwards WARNING Act with utmost care as a fall to the ground might damage the agitator Remove the seal by sliding it out of the shaft Clean all the removed parts with cleaning sanit...

Page 35: ...r too long with an empty hopper or just filled with water and sanitizing solution brings about a quick wear of the beater Drain all solution by opening the shut off valve WARNING Do not touch the sani...

Page 36: ...36 EASY MIX PLUS Easy Mix Plus 2018 07 Rev 03 EN...

Page 37: ...maintenance operations required Below is a list of ordinary maintenance operations Hopper and lid cleaning It must be carried out at the end of each shift Beater unit cleaning It must be carried out a...

Page 38: ...PLIED ACCESSORIES 6 4 ORDERING SPARE PARTS If one or several parts are worn or faulty refer to your dealer to order all necessary spare parts ATTENTION Before using spare parts and or supplied parts i...

Page 39: ...t cut etc a new one dispensing spigot Internal noise Motor or compressor Request the intervention of the service department A bacterial test proved Too many bacteria in the Improve production product...

Reviews: