2.4 MACHINES WITH WATER-COOLED CONDENSER
On machines with water-cooled condenser, water connections (for machine wash and gas cooling) are
placed on the rear panel. The connections are three, all aligned along the same vertical line. Machines
fitted with a water-cooled condenser need to be connected to running water supply or to a cooling tower.
Water must have a pressure of 0.1 MPa (1 bar) at least, and a flow rate at least equal to the
estimated hourly consumption.
Connect inlet pipe marked by plate “Water Inlet” to water supply installing a shut-off valve, and
outlet pipe marked by plate “Water Outlet” to a drain pipe, installing a shut-off valve.
2.4.1 Water valve adjustment
IMPORTANT
If water valve must be reset, this operation shall be carried out by skilled personnel, only.
Valve adjustment must be carried out in such a way that no water flows when machine is off and
lukewarm water flows when machine is on.
NOTE:
Water consumption increases if temperature of inlet water is above 20 °C.
WARNING:
Do not leave the machine in a room with temperature below 0°C without draining water
from the condenser.
2.5
ELECTRIC CONNECTION
The power supply system must comply with the national regulations in force in the place of
installation and provided with an efficient ground connection.
The manufacturer is not responsible for any malfunction or for injury to persons and/or damage
to property resulting from connection to a non-compliant electrical system.
The appliance must be installed according to the current regulations for electrical installation,
by competent and qualified technical personnel meeting the technical and professional
requirements provided for by the legislation in force in the country of installation.
Before connecting the machine to the mains, check that the mains characteristics meet those of
the machine specified in the identification plate applied to the machine itself.
Check that the power supply network is provided with a disconnection device, in compliance
with the installation rules, ensuring complete disconnection from the mains for each pole
(differential circuit breaker), in the conditions of overvoltage category III. The opening
distance of contacts must be at least 3 mm.
Check that the trip level of the differential circuit breaker is ≤ 30mA.
The machine is supplied with power cable; in case of three-phase machine with neutral, the
blue conductor of the power supply cable must be connected to the system neutral.
WARNING
The machine is fitted with an electric supply cable including a yellow/green cable, which
MUST be connected to an appropriate grounding of the electric system.
2.5.1 Equipotential connection
Connection to external equipotential terminal is indicated by symbol.
It is present on the side or on the back of the machine, not to be connected to the protection ground.
The conductor to be used has a cross-section at least equivalent to the one of the connected
conductor with greatest cross-section.
2.8.2 Replacing the power cable
If the machine power cable is damaged, replace it immediately with a cable with the same features.
Replacement must be carried out by qualified personnel only.