NOTE:
The intermittent beating times may also be modified by the user by entering the
User Programming screen (refer to the USER PROGRAMMING paragraph).
COOLING:
Upon selection of the Cooling function, by pressing the
AUTO
button
STOP
easymix
60
plus
a
second menu is displayed, which allows the user to select the type of cooling
based on the product quantity in the hopper. By using the
Increase
and
Decrease
buttons select now one of the following:
* 120 - 40
Full Filling
60 - 40
Half Filling
The cycle starts automatically after 3 seconds or upon pressing the
AUTO
button again.
The machine starts to cool the product and the display shall be as follows:
COOLING
+04°C
+85°C
- the current function on the first line;
- on the second line: the set temperature on the left, the product temperature on
the right, and the temperature decrease curve in the middle.
Beating is always active during Cooling as well.
The temperature to be reached (set temperature) can be edited with the Increase/
Decrease buttons (relevant LED's are on) from 0°C to 90°C.
Once the set temperature has been reached the buzzer rings.
The mix is thermostat-controlled at the set temperature indefinitely with the same
beating of the cycle carried out.
After a few minutes (see the “Timer Backlight” user programming step) the display
backlighting is switched off.
NOTE: