Resistance
Range
resolution
Accuracy
(%
rdg
+
digits
)
400
Ω
0.1
Ω
±
(
0
.
5
%
rdg
+
5d
)
4k
Ω
1
Ω
±
(
0
.
5
%
rdg
+
3d
)
40k
Ω
10
Ω
±
(
0
.
5
%
rdg
+
3d
)
400k
Ω
100
Ω
±
(
0
.
5
%
rdg
+
3d
)
4M
Ω
1 k
Ω
±
(
1
%
rdg
+
5d
)
40M
Ω
10k
Ω
±
(
1
.
5
%
rdg
+
10d
)
Open
circuit
Voltage
:
0
.
45V
Input
protection
:
250V
RMS
Continuity
Test
Continuity
threshold
:
Approx
.
40
Ω
Continuity
threshold
:
2kHz
tone
buzzer
Input
protection
:
250V
RMS
Diode
Test
Test
current
:
0
.
6mA
Open
circuit
voltage
:
Approx
.
3
.
0V
Input
protection
:
250V
RMS
3-5