45
IMC1300_RS232_Rev2.5_070906
<RS232 Command Definition>
● General Guidelines for RS232 Messages
<-----------------------------------------------
Default Baud Rate : 9600
User Set : Yes
Character length : 8
User Set : No
Parity bit : None
User Set : No
Start & Stop Bit : 1
User Set : No
----------------------------------------------->
○ All commands are sent and received as ASCII strings.
○ All commands must include a parameter byte or string except "READ"
Command which is beginning with "B" character.
○ All commands must begin "sharp" character(#), and ending with the carriage
return(CR)
#XXX YYYY <CR>
XXX - Command
YYYY - Parameter
<CR> - Carriage Return Value.
'INVALID' - Command is Wrong. Check command.
'?!' - Parameter is Wrong. Check parameter.
※ <Caution> ※
First Character 'R' means READ and 'S' means SET.
'(quotation mark) is not command data and received data.
<CR> means carriage return value. <CR> is equal to hexa value 0x0d.
' ' means space return value. If return value is 5byte '100 ', 4th and 5th data is
space data(0x20).