5
7. Adjust the upper wire straightener, beginning at
position shown, (Index E) so that the wire points
straight down. Adjust the lower wire
straightener, beginning at the 3:00 o'clock
position, (Index F) so that the wire (Index L)
feeds straight down.
8. Replace the rotator and rotator operating spring.
NOTE:
When changing coils or wire sizes, check
straighteners to insure proper wire feed.
CAUTION
Do not operate stitcher until
operating instructions have been
read and understood-do not
operate stitcher at anytime without
work under the head.
FELT WIPE PADS
LUBRICATION
AND MAINTAINANCE:
(FIGURE 2)
IMPORTANT! In order for the stitchers to operate
properly, the felt wire wipes
MUST
be rotated and
dampened with SAE 20W oil before each new spool
of wire (50,000 to 70,000 stitches). Replace felt
pads when they become so dirty that they cannot be
rotated to a clean spot.
Figure 2
Dirty area of pads has been
slightly rotated so that a clean
area of pads can be used for the
next wire spool.
Rotate
1. After every wire
spool, rotate the
dirty area of the
pads slightly so that
a clean area can be
used for the next
wire spool.
(CTTT2605 Scene 7)
2. Dampen both pads
(about 30 to 40
drops) using an SAE
20W oil.