background image

 

 

MEASUREMENT AND ASSEMBLY MANUAL 

 

Validity of the manual: 21.3.2022 

(40 

×

 1.8 mm) for water draining (not part of delivery) into the pole and 

apply sealing compound to 

the funnel, see Fig. D.1. 

A.3 

Adjust  the  height  of  the  pole  A1  according  to  the  actual  passage  height  (the  pole  height  can  be 
adjusted in the range of + 2 cm) and tighten the four countersunk bolts M8. When fitting the pole to 
the foot, the pole is at the 

 2 cm position of the set height. 

A.4 

Repeat steps 

A.2 

and

 A.3

 for the remaining poles. 

A.5  

Insert the perimeter section A1A3 in the pre-installed pole A1 and pole A3. Do not hold the perimeter 
section by the eaves part only 

 hold it by the main supporting section. Otherwise eaves will likely be 

damaged. 

 

If the  pergola is placed under a roof or truss, it is necessary to allow  for at  least  380 mm  above  the 
pole inserted in the foot for inserting the perimeter section. 

A.6  

Secure the connection of the perimeter section A1A3 and pole A1 by pre-installed bolts (4 countersunk 
bolts M8 for each pole). 

A.7 

Secure the connection of the perimeter section A1A3 and pole A3 by pre-installed bolts (4 countersunk 
bolts M8 for each pole). 

A.8 

Repeat steps 

A.5 

through

 A.7

 for the perimeter section C1C3 and pole C1 and pole C3. 

A.9 

Prior to installing the perimeter section A1C1, insert reinforcement to both sides of the section. Then 
connect the section A1A3 and perimeter section C1C3. 

Prior to installing, apply sealing compound to 

the side cover of the drainage channel, see Fig. D.2.

 Insert the perimeter section A1C1 between the 

pole A1 and pole C1 so that the pre-installed 6HR screws fit in the grooves. Tighten the pre-installed 
6HR screws on both sides of the perimeter section A1C1. 

A.10 

Insert two cup-

head bolts M10×20 to each corner of the frame and tighten.

 

A.11 

Insert one  hexagon-

head bolt M10×340 to  each

  corner  and  tighten.  If  the  pergola  is  placed  under  a 

roof or truss and the room above the pergola is not sufficient for inserting the bolts, do not use the 
bolts. This does not affect the pergola function. 

A.12 

Repeat steps 

A.9 

and

 A.10

 for the perimeter section A3C3. 

A.13 

Check  the  dimensions  of  the  diagonals,  check  the  frame  flatness  and  pole  verticality,  and  adjust  if 
necessary. 

A.14 

If no problem is found, tighten the fastening nuts in the perimeter section, tighten the nuts in feet and 
overlap the gap by the pole cover section. Attach the cover section to the pole (use bolts or silicone). 

A.15 

Insert the individual slats in the corresponding side sockets and secure with locks. The side sockets in 
the perimeter section 

are adjusted to 45°

 slat tilting. The first slat and the last slat must be oriented 

with respect to the limit sections attached to the perimeter sections A1C1 and A3C3. 

A.16 

Connect the motor and lighting, if any, and hide the cables inside the perimeter section and transverse 
section. 

A.17 

If the pergola includes a LED lighting unit, connect it using connecting plugs. 

A.18 

Connect the LED lighting unit to the power supply unit using a cable with Hirschmann terminal. 

A.19 

Test the slat tilting function; the end-of-travel positions are factory-set. It is not possible to adjust the 
limit section for opening, as this will likely lead to the slat mechanism collision. 

A.20 

Attach the side covers to the perimeter sections. 

 

Summary of Contents for ARTOSI

Page 1: ...ricity connections integration of the pergola to the house etc When the pergola is mounted properly slats dropping is made in direction from the motor to the other side Water drainage has to be thus a...

Page 2: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 2 Variant B Variant C...

Page 3: ...at least concrete feet have been prepared in advance or a flat surface is available to which the pergola is to be installed The recommended minimum foot dimensions are 300 300 mm frostproof depth A 1...

Page 4: ...pole A1 and pole C1 so that the pre installed 6HR screws fit in the grooves Tighten the pre installed 6HR screws on both sides of the perimeter section A1C1 A 10 Insert two cup head bolts M10 20 to ea...

Page 5: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 5 GROUND MOUNTING variant A FIGURES TO ILLUSTRATE THE ABOVE ACTIVITIES...

Page 6: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 6...

Page 7: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 7...

Page 8: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 8...

Page 9: ...tallation of the pole A3 and pole C3 Then proceed in accordance with items A 1 through A 4 above B 3 Insert the perimeter section A1A3 to the pre installed pole A3 and press it against the wall mounti...

Page 10: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 10 Wall Mounting Variant B figures to illustrate the above activities B5 B6...

Page 11: ...n both sides of the pergola and the flatness of the perimeter section C 2 Remove the eaves gutter from the perimeter section A1A3 the gutter is not treated with sealing compound at the lower side C 3...

Page 12: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 12 WALL MOUNTING VARIANT C FIGURES TO ILLUSTRATE THE ABOVE ACTIVITIES C3...

Page 13: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 13 C6...

Page 14: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 14 STRUCTURAL PARTS TO BE TREATED WITH SEALING COMPOUND Silicone gutter corner...

Page 15: ...al junction box is located in the section A1 A3 or C1 C3 together with the motors and ensures 220 V power supply for the motors and LED lighting unit The junction box can be removed if necessary to pa...

Page 16: ...DIFFER ACCORDING TO THE METHOD OF CONTROL NUMBER OF MOTORS AND INSTALLED TYPE OF LIGHTING Multi motor Pergolas Controls are carried out by Situo 5 Variation io controller or other types of controller...

Page 17: ...nstalling screen roller blinds If a larger box is used and the roller blinds are attached to the pergola corner joints the rear sides of the boxes will collide and in such a case neither roller blind...

Page 18: ...la is delivered with an IO controller the individual motors are paired with the controller and the extreme positions of the motors are set start and end position of the slats If the IO remote control...

Page 19: ...a year in spring and before winter treat the rubber seal with a product designed for this purpose silicone spray etc Continuously remove coarse dirt such as twigs and branches from the slats of the pe...

Page 20: ...NT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 20 Pergola Anchoring Template The through hole is always oriented to the exterior side of the pergola View of the foot from the inner side of th...

Page 21: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 21 Construction readiness...