Wall Mounting 

 Variant C 

Prior  to  taking  any  measurements,  check  the  surface  to  which  the  pergola  is  to  be  installed.  Measure  the 
surface inclination, difference of level at the house wall and on the opposite side of the pergola. Place the 

pergola  in  accordance  with  the  client’s

  instructions  (to  the  centre,  to  the  left  side,  etc.).  Check  the  wall 

flatness at the perimeter section installation area. 

C.1 

Indicate  on  the  wall  the  position  for  the  installation  of  the  perimeter  section  A1A3,  based  on  the 
measure-taking. Take the measures by starting on one side and then indicating the placement of the 
individual  feet  diagonally.  In  doing  so,  pay  special  attention  to  alignment  and  connection  of  the 
pergola poles to the water outflow. When taking measurements of the openings for the attachment of 
locations A1 and C1 (their height from the surface), take the surface inclination into account. This way 
you will ensure the same passage height on both sides of the pergola and the flatness of the perimeter 
section. 

C.2 

Remove  the  eaves  gutter  from  the  perimeter  section  A1A3  (the  gutter  is  not  treated  with  sealing 
compound at the lower side). 

C.3 

Drill  the  wall  mounting  holes  to  the  space  below  the  eaves  (the  quantity  and  spacing  of  the  holes 
should respect the material to which the pergola is to be anchored). The sections have already been 
predrilled 

 3 holes of 28 mm diameter. 

 

Drill more holes if necessary. 

C.4 

Use  a  suitable  anchoring  system  to  attach  the  perimeter  section  A1A3  (e.g.,  M10  threaded  rod, 
chemical anchor). Apply polymer- or polyurethane-based caulk (1) to the upper edge of the perimeter 
section, see Fig. C.6. 

C.5 

Attach the eaves gutter to the perimeter section A1A3. 

Do not forget to apply sealing compound to 

the lower side! 

 

Then proceed in accordance with items 

A.1 

through

 A.14. 

C.6 

Attach the cover section (4) to the pergola perimeter section and to the wall. Apply compression tape 
(2) to the cover section and attach the section to the perimeter section using Tex bolts with packing 
rubber (3). Apply polymer 

 or polyurethane-based caulk (1) to the upper edge of the cover section (1). 

 

Then proceed in accordance with items 

A.15 

through

 A.20. 

Summary of Contents for ARTOSI

Page 1: ...ricity connections integration of the pergola to the house etc When the pergola is mounted properly slats dropping is made in direction from the motor to the other side Water drainage has to be thus a...

Page 2: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 2 Variant B Variant C...

Page 3: ...at least concrete feet have been prepared in advance or a flat surface is available to which the pergola is to be installed The recommended minimum foot dimensions are 300 300 mm frostproof depth A 1...

Page 4: ...pole A1 and pole C1 so that the pre installed 6HR screws fit in the grooves Tighten the pre installed 6HR screws on both sides of the perimeter section A1C1 A 10 Insert two cup head bolts M10 20 to ea...

Page 5: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 5 GROUND MOUNTING variant A FIGURES TO ILLUSTRATE THE ABOVE ACTIVITIES...

Page 6: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 6...

Page 7: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 7...

Page 8: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 8...

Page 9: ...tallation of the pole A3 and pole C3 Then proceed in accordance with items A 1 through A 4 above B 3 Insert the perimeter section A1A3 to the pre installed pole A3 and press it against the wall mounti...

Page 10: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 10 Wall Mounting Variant B figures to illustrate the above activities B5 B6...

Page 11: ...n both sides of the pergola and the flatness of the perimeter section C 2 Remove the eaves gutter from the perimeter section A1A3 the gutter is not treated with sealing compound at the lower side C 3...

Page 12: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 12 WALL MOUNTING VARIANT C FIGURES TO ILLUSTRATE THE ABOVE ACTIVITIES C3...

Page 13: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 13 C6...

Page 14: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 14 STRUCTURAL PARTS TO BE TREATED WITH SEALING COMPOUND Silicone gutter corner...

Page 15: ...al junction box is located in the section A1 A3 or C1 C3 together with the motors and ensures 220 V power supply for the motors and LED lighting unit The junction box can be removed if necessary to pa...

Page 16: ...DIFFER ACCORDING TO THE METHOD OF CONTROL NUMBER OF MOTORS AND INSTALLED TYPE OF LIGHTING Multi motor Pergolas Controls are carried out by Situo 5 Variation io controller or other types of controller...

Page 17: ...nstalling screen roller blinds If a larger box is used and the roller blinds are attached to the pergola corner joints the rear sides of the boxes will collide and in such a case neither roller blind...

Page 18: ...la is delivered with an IO controller the individual motors are paired with the controller and the extreme positions of the motors are set start and end position of the slats If the IO remote control...

Page 19: ...a year in spring and before winter treat the rubber seal with a product designed for this purpose silicone spray etc Continuously remove coarse dirt such as twigs and branches from the slats of the pe...

Page 20: ...NT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 20 Pergola Anchoring Template The through hole is always oriented to the exterior side of the pergola View of the foot from the inner side of th...

Page 21: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 21 Construction readiness...

Reviews:

Related manuals for ARTOSI