UNPACKING AND STORING THE PERGOLA 

In most cases, the pergola is supplied in wooden crates. We therefore recommend unloading the crates from 
the vehicle using a fork-lift truck. If a fork-lift truck cannot be provided, open the crates on the vehicle and 
carefully unload the individual parts of the pergola and place them on a flat surface 

 crate cover, etc. Check 

the crates and components inside them for any damage caused by the transport. 

Store the pergola in the original packaging. If not installed immediately after unloading, store the pergola in a 
dry place and protect it from direct sunlight. 

Be careful when unpacking the pergola, check whether all parts are intact, do not damage the paintwork. In 
case  of  any  defect,  document  the  defect  and  continue  the  assembly  according  to  the  manual.  Only  skip 
processes where sealing compound is to be applied! (This is due to possible replacement of defective parts, 
does not apply to slats). 

 

1. CONTROL 

Motor with integrated IO receiver  

The control is performed with the Situo 5 variation io controller (or possibly another IO controller). 

If the pergola is delivered with an IO controller, the individual motors are paired with the controller and the 
extreme positions of the motors are set (start and end position of the slats). If the IO remote control is not 
included in the delivery, only the extreme positions of the motors are set. In this case, the motors must be 
paired  with  the  controller  before  the  initial  start-up,  or  other  settings  must  be  made  according  to  the 
instructions  of  the  drive  used.  Do  not  change  the  setting  of  the  extreme  positions  of  the  slats,  they  may 
collide and be damaged!!! If the pergola is equipped with integrated LED lighting, this lighting is paired with 
the  remote  control.  Any  reprogramming  can  be  performed  according  to  the  instructions  for  Somfy  LED 
lighting receiver IO. 

Motor without integrated WT receiver.  

The control is performed by a local wall button connected by a wire path to the pergola drive. If these motors 
are  connected  to  the  control  of  a  smart  home,  the  control  usually  takes  place  via  specific  controls  of  the 
given  manufacturer  (actuators,  applications,  remote  controls).  If  you  use  a  control  system,  first  familiarize 
yourself with the instructions provided. Do not change the setting of the extreme positions of the slats, they 
may collide and be damaged!!! 

Always operate the pergola from a place that allows a complete overview of the movement of the pergola 
roof. 

 

 

 

 

Summary of Contents for ARTOSI

Page 1: ...ricity connections integration of the pergola to the house etc When the pergola is mounted properly slats dropping is made in direction from the motor to the other side Water drainage has to be thus a...

Page 2: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 2 Variant B Variant C...

Page 3: ...at least concrete feet have been prepared in advance or a flat surface is available to which the pergola is to be installed The recommended minimum foot dimensions are 300 300 mm frostproof depth A 1...

Page 4: ...pole A1 and pole C1 so that the pre installed 6HR screws fit in the grooves Tighten the pre installed 6HR screws on both sides of the perimeter section A1C1 A 10 Insert two cup head bolts M10 20 to ea...

Page 5: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 5 GROUND MOUNTING variant A FIGURES TO ILLUSTRATE THE ABOVE ACTIVITIES...

Page 6: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 6...

Page 7: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 7...

Page 8: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 8...

Page 9: ...tallation of the pole A3 and pole C3 Then proceed in accordance with items A 1 through A 4 above B 3 Insert the perimeter section A1A3 to the pre installed pole A3 and press it against the wall mounti...

Page 10: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 10 Wall Mounting Variant B figures to illustrate the above activities B5 B6...

Page 11: ...n both sides of the pergola and the flatness of the perimeter section C 2 Remove the eaves gutter from the perimeter section A1A3 the gutter is not treated with sealing compound at the lower side C 3...

Page 12: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 12 WALL MOUNTING VARIANT C FIGURES TO ILLUSTRATE THE ABOVE ACTIVITIES C3...

Page 13: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 13 C6...

Page 14: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 14 STRUCTURAL PARTS TO BE TREATED WITH SEALING COMPOUND Silicone gutter corner...

Page 15: ...al junction box is located in the section A1 A3 or C1 C3 together with the motors and ensures 220 V power supply for the motors and LED lighting unit The junction box can be removed if necessary to pa...

Page 16: ...DIFFER ACCORDING TO THE METHOD OF CONTROL NUMBER OF MOTORS AND INSTALLED TYPE OF LIGHTING Multi motor Pergolas Controls are carried out by Situo 5 Variation io controller or other types of controller...

Page 17: ...nstalling screen roller blinds If a larger box is used and the roller blinds are attached to the pergola corner joints the rear sides of the boxes will collide and in such a case neither roller blind...

Page 18: ...la is delivered with an IO controller the individual motors are paired with the controller and the extreme positions of the motors are set start and end position of the slats If the IO remote control...

Page 19: ...a year in spring and before winter treat the rubber seal with a product designed for this purpose silicone spray etc Continuously remove coarse dirt such as twigs and branches from the slats of the pe...

Page 20: ...NT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 20 Pergola Anchoring Template The through hole is always oriented to the exterior side of the pergola View of the foot from the inner side of th...

Page 21: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 21 Construction readiness...

Reviews: