6B 

Luminous intensity: 

 

 

 

 

 

 

 

 

  2.1. Description of the fixture   

 

 

 
 
 
 
 
 
 
 

 

The  head  can  be  locked  for  transportation-the  tilt  lock  button  (4)  is  pushed  and  the  pan 

lock/unlock lever (6) is lock position. To unlock the head, press the tilt unlock button (5) and 

move the pan lock/unlock lever (6) to unlock position.

 

Caution: The head and yoke must be unlocked before operation! Check the pan/tilt 
locks! 

 
  2.2. Inserting/Exchanging rotating gobos   

 

DANGER! 

Install the gobos with the device switched off only. 

Unplug from mains before changing gobos!

 

Open the cover by loosening the fastening screw at the sides of the cover. 

If you wish to use other forms and patterns as the standard-gobos, or if the gobos are to be 

exchanged, remove the fixation ring with an appropriate tool. Remove the gobo and insert 

the new gobo. Press the fixation-ring together and insert it in the front of the gobo. 

1. Yoke 

2. Front panel 

3. Moving head 

4. Tilt lock button (red) 

5. Tilt unlock button (green) 

6. Pan lock/unlock lever 

7. Handle 

8. Base 

7B 

 

 

CAUTION! 

Never unscrew the screws of the rotating gobo as the ball bearing 

will otherwise be opened!

 

 
  3. Lamp  

 

 

WARNING

 

Because  of  its  high  internal  pressure,  there  might  be  a  risk  that  the  Discharge  lamp 

would explode during operation. The lamp emits intense UV radiation which is harmful 

to  the  eyes  and  skin. The  high  luminance  of  the  arc  can  cause  severe  damage  to  the 

retina if looks directly at the lamp. 

  HTI 700W / D4-75 or HTI 575W / D4-75

 

1. Always switch off the main supply and never handle 

the lamp or luminaire when it is hot. 

2. Do not touch the bulb with bare hands. If this 

happens, clean the lamp with denatured alcohol 

and wipe it with a lint free cloth before installation. 

3. The lamp generates UV radiation. Never operate the 

lamp without appropriate shielding. 

4. When  burning,  the  lamp  operates  at  high  pressure 

and there is a slight risk of arc tube rupture. The risk 

increases  with  age,  temperature  and  improper 

handling of the lamp. Do not use the lamp any longer 

than its lifespan. 

5. Make sure the lamp is located in the center of the reflector for the best spot. 

In case of replacement of the lamp or maintenance, do not open the 

  fixture within 15 minutes until the unit cools down after switching off. 

Summary of Contents for imove 700s

Page 1: ...Description of the fixture 2 2 Inserting Exchanging rotating gobos 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 4 3 Home Position Adjustment 4 4 Easy controller 5 How To Control T...

Page 2: ...ot z In the event of serious operating problem o sp t using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Plea...

Page 3: ...for transporting protection Focus Automatic focus by DMX controls Iris Motorized iris for different beam diameters Iris Speed control 5B DMX Channels Standard DMX512 signal addressing and can be contr...

Page 4: ...unscrew the screws of the rotating gobo as the ball bearing will otherwise be opened 3 Lamp WARNING Because of its high internal pressure there might be a risk that the Discharge lamp would explode d...

Page 5: ...of the lamp into place Make sure it fits correctly into the socket Please refer to the diagram to know how to put the lamp in correct position 9B 4 How To Set The Unit 4 1 Control Panel MONITOR To sh...

Page 6: ...previous functions without any change press the ESC button StandBy Mode Press the ENTER button and turn jog wheel up to when the StandBy Mode is shown on the monitor Pressing ENTER button and the dis...

Page 7: ...been selected press the ENTER button to setup or automatically return to the main functions without any change after 10 seconds To go back to the previous functions without any change press the ESC b...

Page 8: ...any change after 10 seconds Dimmer offset Press the ENTER button for at least 12 seconds into offset mode turn jog wheel up to when the Dimmer offset is shown on the monitor Pressing ENTER button and...

Page 9: ...on the monitor Pressing ENTER button and the display will blink Use jog wheel to adjust the iris home position Once the position has been selected press the ENTER button to setup or automatically retu...

Page 10: ...18B 5 2 DMX 512 Configuration 19B...

Page 11: ...ble cannot be branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the sys...

Page 12: ...erence to DMX interface circuit C No response to the sound 1 Make sure the unit is not receiving DMX signal 2 Check microphone to see if it is good by tapping the microphone D One of the channels is n...

Page 13: ...n cause greater accumulation of dirt on the unit s optics y Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external optics at least every 20 days...