6B
Luminous intensity:
2.1. Description of the fixture
The head can be locked for transportation-the tilt lock button (4) is pushed and the pan
lock/unlock lever (6) is lock position. To unlock the head, press the tilt unlock button (5) and
move the pan lock/unlock lever (6) to unlock position.
Caution: The head and yoke must be unlocked before operation! Check the pan/tilt
locks!
2.2. Inserting/Exchanging rotating gobos
DANGER!
Install the gobos with the device switched off only.
Unplug from mains before changing gobos!
Open the cover by loosening the fastening screw at the sides of the cover.
If you wish to use other forms and patterns as the standard-gobos, or if the gobos are to be
exchanged, remove the fixation ring with an appropriate tool. Remove the gobo and insert
the new gobo. Press the fixation-ring together and insert it in the front of the gobo.
1. Yoke
2. Front panel
3. Moving head
4. Tilt lock button (red)
5. Tilt unlock button (green)
6. Pan lock/unlock lever
7. Handle
8. Base
7B
CAUTION!
Never unscrew the screws of the rotating gobo as the ball bearing
will otherwise be opened!
3. Lamp
WARNING
Because of its high internal pressure, there might be a risk that the Discharge lamp
would explode during operation. The lamp emits intense UV radiation which is harmful
to the eyes and skin. The high luminance of the arc can cause severe damage to the
retina if looks directly at the lamp.
HTI 700W / D4-75 or HTI 575W / D4-75
1. Always switch off the main supply and never handle
the lamp or luminaire when it is hot.
2. Do not touch the bulb with bare hands. If this
happens, clean the lamp with denatured alcohol
and wipe it with a lint free cloth before installation.
3. The lamp generates UV radiation. Never operate the
lamp without appropriate shielding.
4. When burning, the lamp operates at high pressure
and there is a slight risk of arc tube rupture. The risk
increases with age, temperature and improper
handling of the lamp. Do not use the lamp any longer
than its lifespan.
5. Make sure the lamp is located in the center of the reflector for the best spot.
In case of replacement of the lamp or maintenance, do not open the
fixture within 15 minutes until the unit cools down after switching off.