background image

2B 

  1. Safety Instruction  

 

 

WARNING  

 

z

 

Please keep this User Guide for future consultation. If you sell the unit to another user, 

be sure that they also receive this instruction booklet. 

z

 

Unpack and check carefully there is no transportation damage before using the unit. 

z

 

Before  operating,  ensure  that  the  voltage  and  frequency  of  power  supply  match  the 

power requirements of the unit. 

z

 

The unit is designed for use with the HTI 700W / D4-75 or HTI 575W / D4-75 lamps. Do 

not use any other type of lamp. 

z

 

It’s  important  to  ground  the  yellow/green  conductor  to  earth  in  order  to  avoid  electric 

shock. 

z

 

The unit is for indoor use only. Use only in a dry location. 

z

 

The  unit  must  be  installed  in  a  location  with  adequate  ventilation,  at  least  50cm  from 

adjacent surfaces. Be sure that no ventilation slots are blocked. 

z

 

Disconnect main power before fuse/lamp replacement or servicing.

 

z

 

Replace fuse/lamp only with the same type. 

z

 

Make sure there are no flammable materials close to the unit while operating, as it is fire 

hazard. 

z

 

Use safety chain when fixes this unit. Don’t handle the unit by taking its head only, but 

always by taking its base. 

z

 

Maximum ambient temperature is TA : 40

. Don’t operate it where the temperature is 

higher than this. 

z

 

Unit  surface  temperature  may  reach  up  to  85

.  Don’t  touch  the  housing  bare-hand 

during its operation, and allow about 15 minutes to cool down before replacing bulb or 

serving, as the unit could be very hot. 

z

 

In the event of serious operating problem, ospt using the unit immediately. Never try to 

repair the unit by yourself. Repairs carried out by unskilled people can lead to damage 

or  malfunction.  Please  contact  the  nearest  authorized  technical  assistance  center. 

Always use the same type spare parts. 

z

 

Don’t connect the device to any dimmer pack. 

z

 

Do not touch any wire during operation as there might be a hazard of electric shock.

 

 

Please read carefully the instruction, which includes important 

information about the installation, usage and maintenance. 

3B 

Warning 

z

 

To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or 

moisture. 

z

 

Never touch bulb with bare fingers, as it is very hot after using. 

z

 

Hot lamp explosion hazard. Do not open the unit within five minutes after switching off. 

z

 

Do not start on the unit without bulb enclosure or when housing is damaged. 

z

 

The  housing,  the  lenses,  or  the  ultraviolet  filter  must  be  replaced  if  they  are  visibly 

damaged. 

z

 

Do not look directly at the light while the bulb is on. 

 

Caution 

There are no user serviceable parts inside the unit. Do not open the housing or attempt any 

repairs by yourself. In the unlikely event your unit may require service, please contact your 

nearest dealer. 

 

Installation 

The unit should be mounted via its mounting system ( as shown below ) on the bottom of the 

base. Use clamps to fix the unit to truss. Always ensure that the unit is firmly fixed to avoid 

vibration  and  slipping  while  operating.  Always  ensure  that  the  structure  to  which  you  are 

attaching the unit is secure and is able to support a weight of 50 kgs for each unit. 

 

 

Summary of Contents for imove 700s

Page 1: ...Description of the fixture 2 2 Inserting Exchanging rotating gobos 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 4 3 Home Position Adjustment 4 4 Easy controller 5 How To Control T...

Page 2: ...ot z In the event of serious operating problem o sp t using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Plea...

Page 3: ...for transporting protection Focus Automatic focus by DMX controls Iris Motorized iris for different beam diameters Iris Speed control 5B DMX Channels Standard DMX512 signal addressing and can be contr...

Page 4: ...unscrew the screws of the rotating gobo as the ball bearing will otherwise be opened 3 Lamp WARNING Because of its high internal pressure there might be a risk that the Discharge lamp would explode d...

Page 5: ...of the lamp into place Make sure it fits correctly into the socket Please refer to the diagram to know how to put the lamp in correct position 9B 4 How To Set The Unit 4 1 Control Panel MONITOR To sh...

Page 6: ...previous functions without any change press the ESC button StandBy Mode Press the ENTER button and turn jog wheel up to when the StandBy Mode is shown on the monitor Pressing ENTER button and the dis...

Page 7: ...been selected press the ENTER button to setup or automatically return to the main functions without any change after 10 seconds To go back to the previous functions without any change press the ESC b...

Page 8: ...any change after 10 seconds Dimmer offset Press the ENTER button for at least 12 seconds into offset mode turn jog wheel up to when the Dimmer offset is shown on the monitor Pressing ENTER button and...

Page 9: ...on the monitor Pressing ENTER button and the display will blink Use jog wheel to adjust the iris home position Once the position has been selected press the ENTER button to setup or automatically retu...

Page 10: ...18B 5 2 DMX 512 Configuration 19B...

Page 11: ...ble cannot be branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the sys...

Page 12: ...erence to DMX interface circuit C No response to the sound 1 Make sure the unit is not receiving DMX signal 2 Check microphone to see if it is good by tapping the microphone D One of the channels is n...

Page 13: ...n cause greater accumulation of dirt on the unit s optics y Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external optics at least every 20 days...