1.0

Installation Instructions for

Vance and Lance 13 Flush Mount

700FMVNC13, 700FMLNC13

920FMVANLANS

CAUTION RISK OF FIRE

-

This product must be installed in accordance with

the applicable installation code by a person familiar

with the construction and operation of the product

and the hazards involved.

Use minimum 90°c supply conductors.

CEILING COLLECTION

G

P

I

:

ENERAL RODUCT NFORMATION

These fixtures are intended to be installed
utilizing

compliant junction boxes.

NEC

This product is suitable for damp locations.

This product can be dimmed with a low-voltage electronic
dimmer.

This instruction shows a typical installation.

1A

Ground the fixture in accordance with local electrical
codes.

Connect the black fixture wire to the hot power line
wire with a wire nut.

Connect the white fixture wire to the neutral power line
wire with a wire nut.

1

2

3

2

1

3

Install the fixture

Align the through holes in the fixture base with the #8-
32 screws to junction box.

Firmly tighten the #8-32 screws to hold the fixture base
in place through the next steps.

4

3

5

1B

1B

2

4

5

Note

: depending on the dimensions of the J-box, you

may use either the inner or outer through holes.

1

FIXTURE

BASE

#8-32
SCREW

5