CCW-R-2**B INSTRUCTION MANUAL
11 CAUSES AND ACTIONS FOR ERRORS AND FAILURES
11-11
[WARNING:
OVERWEIGHT ERROR]
1. A proper result of combination
weighing cannot be obtained, and all
combination weights are underweight
or overweight.
2. During rechecking, overweight occurs
due to vibration, etc.
•
This error is displayed
when overweight dump
count is less than the set
count or the dump count is
set to “0”.
1. Decrease the feeder amplitude or time by
making feeder adjustment.
2. Decrease the amount of products supplied to the
dispersion table.
3. Increase the set value of the upper weight limit.
[RCU fan stopped. Contact to
factory service.]
1. The RCU fan connector is
disconnected.
2. The RCU fan is broken.
1. Turn off the main power switch to avoid
damaging the boards. Contact the distributor or
Ishida customer support to request repair
service.
[WARNING: AUTO ZERO
ERROR]
1. The weigh hopper is constantly loaded. 1. Check the weigh hopper.
2. There is a possibility of malfunctioning of the
weight sensor. Contact the distributor or Ishida
customer support.
[WARNING:
COMMUNICATION
ERROR]
1. Error has occurred in the
communication network.
1. Contact the distributor or Ishida customer
support to request repair service.
[WARNING: RECHECK
ERROR]
1. The result of the combination by count
is not within “target weight - lower
weight limit” and “target
upper weight limit”.
•
This error occurs when the
count set weighing
(optional) is used.
1. Check the set value of the upper and lower
weight limits.
**ERROR
/STEPPING MOTOR
DRIVE ERROR
Hopper does not open/close
properly.
(**: PH, WH, and BH)
1. Product is jammed.
•
This error occurs in the
event of the hopper
malfunction in cases that
the products are jammed in
the hopper or the motor
does not operate properly
due to excessive load.
1. Remove the jammed products from the hopper.
2. Inspect for looseness, breakage or loss of the
screws of the hopper. If unable to repair, contact
the distributor or Ishida customer support to
request repair service.
3. If the error occurs again after the error is once
cleared, check the timing.
If this error still occurs, turn off the main power
switch and turn it on again.
Table 11-4 Error Display List (Pattern 3) (Continued)
Error Name/
Error Description
Cause
Action
Summary of Contents for CCW-R-2 B Series
Page 4: ... 2 ...
Page 20: ...CCW R 2 B INSTRUCTION MANUAL 12 ...
Page 28: ...1 SAFETY PRECAUTIONS CCW R 2 B INSTRUCTION MANUAL 1 8 ...
Page 115: ...CCW R 2 B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS 6 3 ...
Page 116: ...6 FUNCTIONS OF THE OPERATION SCREENS CCW R 2 B INSTRUCTION MANUAL 6 4 ...
Page 117: ...CCW R 2 B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS 6 5 ...
Page 118: ...6 FUNCTIONS OF THE OPERATION SCREENS CCW R 2 B INSTRUCTION MANUAL 6 6 ...
Page 119: ...CCW R 2 B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS 6 7 ...
Page 120: ...6 FUNCTIONS OF THE OPERATION SCREENS CCW R 2 B INSTRUCTION MANUAL 6 8 ...
Page 288: ...7 USEFUL FUNCTIONS CCW R 2 B INSTRUCTION MANUAL 7 14 ...
Page 310: ...8 OPTIONAL FUNCTIONS CCW R 2 B INSTRUCTION MANUAL 8 22 ...
Page 374: ...11 CAUSES AND ACTIONS FOR ERRORS AND FAILURES CCW R 2 B INSTRUCTION MANUAL 11 26 ...
Page 463: ... 0 00 102 4577 052 ...
Page 465: ... 00 1 11 2 34 34 2 5 5 66 6 7276 89 4 0 8 03 0 0344 A93 A 3 8 A B 4A 3 3C 5 ...
Page 466: ... 107 2454 00 ...
Page 467: ... 107 2452 02 ...
Page 470: ... 107 2458 04 ...
Page 471: ... 0 1 0 1 0 1 0 1 0 1 0 1 2 3 105 0490 021 ...
Page 473: ... 0 123 2456781597 0 102 3901 053 00 ...
Page 476: ... 0 0 1 2 1 1 2 1 1 1 3 33 086 6134 04 ...
Page 477: ...086 6135 08 ...
Page 488: ...10 INDEX CCW R 2 B INSTRUCTION MANUAL ...
Page 490: ......
Page 491: ......
Page 492: ......