[OVERSCALE ERROR]
/A weight exceeding TW +
UL is detected.
1. Excessive product fed into weigh hopper.
2. Infeed position from the infeeder is one-sided.
3. Position of the infeed control phototube is not
proper.
•
This error occurs when weighted
product over “target upper
weight limit” or “set target count +
upper count limit” is supplied to
one head, and when the number of
overscale heads becomes more than
the set value.
If an overscale head exists during
operation, an overscale error will
occur when the operation is
stopped, even if the number of
overscale heads is less than the set
value.
Also for full scale heads (when the
weighted product exceeding the
weight limit is supplied to one
head), an overscale error will occur
when the operation is stopped.
•
If overscale is set to be
automatically discharged,
production will not be stopped due
to this error, and a warning message
will be displayed on the lower side
of the screen of the remote control
unit.
However, for full scale heads that
do not discharge products
automatically during operation, an
overscale error will occur when the
operation is stopped.
1. Decrease the feeder amplitude or time
by making feeder adjustment.
2. Adjust the position of the infeeder
(supply chute) so that the infeed
position comes to the center of the
dispersion table.
3. Too many products are pooled in the
dispersion unit because the position of
the infeed control phototube is too high.
Lower the position of the infeed control
phototube.
**ERROR
/STEPPING MOTOR
DRIVE ERROR
Hopper does not open/close
properly.
(**: PH, WH, BH, RS, TH,
and DTH)
1. Product is jammed.
•
This error occurs in the event of the
hopper malfunction in cases that
the products are jammed in the
hopper or the motor does not
operate properly due to excessive
load.
1. Remove the jammed products from the
hopper.
2. Inspect for looseness, breakage or loss
of the screws of the hopper. If unable to
repair, contact the distributor or Ishida
customer support to request repair
service.
3. If the error occurs again after the error
is once cleared, check the timing.
If this error still occurs, turn off the
main power switch and turn it on again.
Table 11-2 Error Display List (Pattern 1) (Continued)
Error Name/
Error Description
Cause
Action
Summary of Contents for CCW-R-2 B Series
Page 4: ... 2 ...
Page 20: ...CCW R 2 B INSTRUCTION MANUAL 12 ...
Page 28: ...1 SAFETY PRECAUTIONS CCW R 2 B INSTRUCTION MANUAL 1 8 ...
Page 115: ...CCW R 2 B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS 6 3 ...
Page 116: ...6 FUNCTIONS OF THE OPERATION SCREENS CCW R 2 B INSTRUCTION MANUAL 6 4 ...
Page 117: ...CCW R 2 B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS 6 5 ...
Page 118: ...6 FUNCTIONS OF THE OPERATION SCREENS CCW R 2 B INSTRUCTION MANUAL 6 6 ...
Page 119: ...CCW R 2 B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS 6 7 ...
Page 120: ...6 FUNCTIONS OF THE OPERATION SCREENS CCW R 2 B INSTRUCTION MANUAL 6 8 ...
Page 288: ...7 USEFUL FUNCTIONS CCW R 2 B INSTRUCTION MANUAL 7 14 ...
Page 310: ...8 OPTIONAL FUNCTIONS CCW R 2 B INSTRUCTION MANUAL 8 22 ...
Page 374: ...11 CAUSES AND ACTIONS FOR ERRORS AND FAILURES CCW R 2 B INSTRUCTION MANUAL 11 26 ...
Page 463: ... 0 00 102 4577 052 ...
Page 465: ... 00 1 11 2 34 34 2 5 5 66 6 7276 89 4 0 8 03 0 0344 A93 A 3 8 A B 4A 3 3C 5 ...
Page 466: ... 107 2454 00 ...
Page 467: ... 107 2452 02 ...
Page 470: ... 107 2458 04 ...
Page 471: ... 0 1 0 1 0 1 0 1 0 1 0 1 2 3 105 0490 021 ...
Page 473: ... 0 123 2456781597 0 102 3901 053 00 ...
Page 476: ... 0 0 1 2 1 1 2 1 1 1 3 33 086 6134 04 ...
Page 477: ...086 6135 08 ...
Page 488: ...10 INDEX CCW R 2 B INSTRUCTION MANUAL ...
Page 490: ......
Page 491: ......
Page 492: ......