CCW-R-2**B INSTRUCTION MANUAL
8 OPTIONAL FUNCTIONS
8-13
•
In count set weighing, after the combination weighing is completed, the weighing result is
checked to see if it is within “target upper weight limit” and “target weight - lower
weight limit”.
Products will not be discharged if the value is not within this range, so care must be taken in
setting upper and lower weight limits. A setting example is shown below.
Example: When the target count is 10, the upper count limit is 1, and the piece weight is
5.00g (4.80 to 5.20g)
Target weight: 50g (5.00
×
10)
Lower weight limit: 2g (50.0 - 4.80
×
10)
Upper weight limit: 7.2g (5.20
×
11 - 50.0)
4
[Piece Weight] key
Sets the weight for a single piece of product.
The number of pieces supplied to each hopper is calculated based on this piece
weight value.
5
[Piece Weight Revision] radio button
Specifies whether the device automatically updates the piece weight ([1/1], [1/
2], [1/4]) or not ([Off]).
When set to [Off], the number of pieces supplied to each weigh hopper is
calculated based on the specified piece weight value.
When the piece weight varies, set this field to perform update so that the piece
weight is automatically updated and the number of pieces supplied to each
weigh hopper is calculated based on the updated piece weight value.
Furthermore, there are three options for the update setting ([1/1], [1/2], and [1/
4]) depending on the range to which the updated operation can be performed.
Set this option to [1/1] in normal operation.
[1/1]: Use this option if no error occurs in converting to the number of pieces
when the target amount of product is supplied to one head.
[1/2]: Use this option if no error occurs in converting to the number of pieces
when half of the target amount of product is supplied to one head.
[1/4]: Use this option if no error occurs in converting to the number of pieces
when one quarter of the target amount of product is supplied to one head.
•
Refer to “8.3.2 Piece Weight Revision” for details regarding the
piece weight update.
Table 8-5 Items and Functions of [Count Setting] Index Screen (Continued)
No.
Name
Function
Target Count
Upper Count
10 Piece
11 Piece
Target Limit
Lower Limit
Upper Limit
-2.0g
50.0g
+7.2g
Summary of Contents for CCW-R-2 B Series
Page 4: ... 2 ...
Page 20: ...CCW R 2 B INSTRUCTION MANUAL 12 ...
Page 28: ...1 SAFETY PRECAUTIONS CCW R 2 B INSTRUCTION MANUAL 1 8 ...
Page 115: ...CCW R 2 B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS 6 3 ...
Page 116: ...6 FUNCTIONS OF THE OPERATION SCREENS CCW R 2 B INSTRUCTION MANUAL 6 4 ...
Page 117: ...CCW R 2 B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS 6 5 ...
Page 118: ...6 FUNCTIONS OF THE OPERATION SCREENS CCW R 2 B INSTRUCTION MANUAL 6 6 ...
Page 119: ...CCW R 2 B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS 6 7 ...
Page 120: ...6 FUNCTIONS OF THE OPERATION SCREENS CCW R 2 B INSTRUCTION MANUAL 6 8 ...
Page 288: ...7 USEFUL FUNCTIONS CCW R 2 B INSTRUCTION MANUAL 7 14 ...
Page 310: ...8 OPTIONAL FUNCTIONS CCW R 2 B INSTRUCTION MANUAL 8 22 ...
Page 374: ...11 CAUSES AND ACTIONS FOR ERRORS AND FAILURES CCW R 2 B INSTRUCTION MANUAL 11 26 ...
Page 463: ... 0 00 102 4577 052 ...
Page 465: ... 00 1 11 2 34 34 2 5 5 66 6 7276 89 4 0 8 03 0 0344 A93 A 3 8 A B 4A 3 3C 5 ...
Page 466: ... 107 2454 00 ...
Page 467: ... 107 2452 02 ...
Page 470: ... 107 2458 04 ...
Page 471: ... 0 1 0 1 0 1 0 1 0 1 0 1 2 3 105 0490 021 ...
Page 473: ... 0 123 2456781597 0 102 3901 053 00 ...
Page 476: ... 0 0 1 2 1 1 2 1 1 1 3 33 086 6134 04 ...
Page 477: ...086 6135 08 ...
Page 488: ...10 INDEX CCW R 2 B INSTRUCTION MANUAL ...
Page 490: ......
Page 491: ......
Page 492: ......