Ç°Ó
*Ê>ÃÃ}iÌ
7.2.1
For the ICP with electronik
The pin assignment of the connection cable for the serial interface:
Please, consider the following notes if you want to custom-specifically setup the optional
supplementary inputs/outputs:
iÌÊÞÊëiV>ÃÌÃÊV>ÀÀÞ}ÊÕÌÊÌ iÊÜÀÊÃViÊÌ iÀÜÃiÊ`>}iÀÊiÝÃÌÃÊvÀÊÞÕÀÊvit
The numbers in the circles refer to the figure of the controller printed circuit board (page 19).
/ÊÌ iÊÓ{Ê6ÊÕÌ«ÕÌÃ\
You can tap the voltage at the 9-pin Sub D connector
➉
.
The switching outputs OPTO-5 and OPTO-6 are carried out with optical isolators with
emitters led outwards. They are available for signaling. These outputs are not disconnected
in case of Emergency-Off.
You must connect your loads against GND 24 V I/O (pins 6 to 9).
The maximum switching current should not exceed 15 mA!
The switching outputs are not short-circuit-protected.
Connection example:
Pin
Description
1
+ 24 V I/O voltage
2
out
OPTO-5 (bit 5) open emitters
3
out
OPTO-6 (bit 6) open emitters
4
free
5
+ 24 V I/O voltage
6
GND 24 V
7
GND 24 V
8
GND 24 V
9
GND 24 V